Environment - simulationEnvironment: startTime=0 stopTime=15 tolerance=1e-06 numberOfIntervals=75000 stepSize=0.0002 Regular simulation: ./Modelica_3.2.2_Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2Pulse.ThyristorBridge2Pulse_DC_Drive -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00714147s reading init.xml | | | | | | 0.000724629s reading info.xml | | | | | | 0.000108804s [ 0.0%] pre-initialization | | | | | | 0.00021381s [ 0.0%] initialization | | | | | | 0.000142327s [ 0.0%] steps | | | | | | 0.322017s [ 1.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 8.93483s [ 27.5%] event-handling | | | | | | 0.0518309s [ 0.2%] overhead | | | | | | 23.125s [ 71.3%] simulation | | | | | | 32.4341s [100.0%] total | | | | | events | | | | | | 4623 state events | | | | | | 1500 time events | | | | | solver: dassl | | | | | | 250336 steps taken | | | | | | 322407 calls of functionODE | | | | | | 103312 evaluations of jacobian | | | | | | 2629 error test failures | | | | | | 0 convergence test failures | | | | | | 17.0349s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.