Environment - simulationEnvironment: startTime=1.6848e+07 stopTime=1.728e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.IdealHeatingCoolingSummer -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.04.20 03:09 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/08/2017 Continuing Simulation at 01/08/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/15/2017 Continuing Simulation at 01/15/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/22/2017 Continuing Simulation at 01/22/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/29/2017 Continuing Simulation at 01/29/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/05/2017 Continuing Simulation at 02/05/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/12/2017 Continuing Simulation at 02/12/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/19/2017 Continuing Simulation at 02/19/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/26/2017 Continuing Simulation at 02/26/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/05/2017 Continuing Simulation at 03/05/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/12/2017 Continuing Simulation at 03/12/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/19/2017 Continuing Simulation at 03/19/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/26/2017 Continuing Simulation at 03/26/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/02/2017 Continuing Simulation at 04/02/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/09/2017 Continuing Simulation at 04/09/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/16/2017 Continuing Simulation at 04/16/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/23/2017 Continuing Simulation at 04/23/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/30/2017 Continuing Simulation at 04/30/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/07/2017 Continuing Simulation at 05/07/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/14/2017 Continuing Simulation at 05/14/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/21/2017 Continuing Simulation at 05/21/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/28/2017 Continuing Simulation at 05/28/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/04/2017 Continuing Simulation at 06/04/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/11/2017 Continuing Simulation at 06/11/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/18/2017 Continuing Simulation at 06/18/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/25/2017 Continuing Simulation at 06/25/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=07/02/2017 Continuing Simulation at 07/02/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=07/09/2017 Continuing Simulation at 07/09/2017 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | The following assertion has been violated at time 16852838.400000 | | | | noEvent(flo.att.vol.medium.T <= 423.15) assert | info | In Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.IdealHeatingCoolingSummer.flo.att.vol.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air". assert | error | No event found, but assert was triggered. Throwing now! Writing final SQL reports EnergyPlus Run Time=00hr 00min 5.72sec EnergyPlus Completed Successfully.