Environment - simulationEnvironment: startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_latest_Buildings.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ1 -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.04.27 06:17 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Warming up {12} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | *** Warning in Buildings.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ1.bui.terUni.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | *** Warning in Buildings.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ1.bui.terUni.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0368912s reading init.xml | | | | | | 0.00336392s reading info.xml | | | | | | 0.00125545s [ 0.0%] pre-initialization | | | | | | 8.31409s [ 83.1%] initialization | | | | | | 6.5503e-05s [ 0.0%] steps | | | | | | 0.0519985s [ 0.5%] solver (excl. callbacks) | | | | | | 0.00843656s [ 0.1%] creating output-file | | | | | | 0.510427s [ 5.1%] event-handling | | | | | | 0.0341109s [ 0.3%] overhead | | | | | | 1.08487s [ 10.8%] simulation | | | | | | 10.0053s [100.0%] total | | | | | events | | | | | | 1007 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 38738 steps taken | | | | | | 55749 calls of functionODE | | | | | | 12007 evaluations of jacobian | | | | | | 1185 error test failures | | | | | | 13 convergence test failures | | | | | | 0.584224s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 2.21sec EnergyPlus Completed Successfully.