Environment - simulationEnvironment: startTime=0 stopTime=5000 tolerance=1e-06 numberOfIntervals=2500 stepSize=2 Regular simulation: ./Buildings_latest_Buildings.DHC.ETS.Combined.Subsystems.Validation.WatersideEconomizer -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (pum2Pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum2Pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Buildings.DHC.ETS.Combined.Subsystems.Validation.WatersideEconomizer.pum2Pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pum2Pum.per.haveWMot_nominal or not (pum2Pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum2Pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Buildings.DHC.ETS.Combined.Subsystems.Validation.WatersideEconomizer.pum2Pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (pum2Val.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum2Val.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Buildings.DHC.ETS.Combined.Subsystems.Validation.WatersideEconomizer.pum2Val: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pum2Val.per.haveWMot_nominal or not (pum2Val.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum2Val.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Buildings.DHC.ETS.Combined.Subsystems.Validation.WatersideEconomizer.pum2Val: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0418563s reading init.xml | | | | | | 0.0036111s reading info.xml | | | | | | 0.00233441s [ 1.4%] pre-initialization | | | | | | 0.00116613s [ 0.7%] initialization | | | | | | 1.594e-05s [ 0.0%] steps | | | | | | 0.00512932s [ 3.0%] solver (excl. callbacks) | | | | | | 0.00755074s [ 4.4%] creating output-file | | | | | | 0.048791s [ 28.3%] event-handling | | | | | | 0.0237733s [ 13.8%] overhead | | | | | | 0.0835139s [ 48.5%] simulation | | | | | | 0.172275s [100.0%] total | | | | | events | | | | | | 27 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 981 steps taken | | | | | | 1283 calls of functionODE | | | | | | 406 evaluations of jacobian | | | | | | 21 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00713656s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.