Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_8_Buildings.ThermalZones.Detailed.Examples.MixedAirCO2 -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated at time 0.000000 | | | | false assert | warning | Nominal variable violating max constraint: roo.irRadExc.J[1] <= 0.0, has value: 3350.12 assert | warning | The following assertion has been violated at time 0.000000 | | | | false assert | warning | Nominal variable violating max constraint: roo.irRadExc.J[2] <= 0.0, has value: 3350.12 assert | warning | The following assertion has been violated at time 0.000000 | | | | false assert | warning | Nominal variable violating max constraint: roo.irRadExc.J[3] <= 0.0, has value: 3350.12 assert | warning | The following assertion has been violated at time 0.000000 | | | | false assert | warning | Nominal variable violating max constraint: roo.irRadExc.J[4] <= 0.0, has value: 3350.12 assert | warning | The following assertion has been violated at time 0.000000 | | | | false assert | warning | Nominal variable violating max constraint: roo.irRadExc.J[5] <= 0.0, has value: 3350.12 assert | warning | The following assertion has been violated at time 0.000000 | | | | false assert | warning | Nominal variable violating max constraint: roo.irRadExc.J[6] <= 0.0, has value: 3350.12 assert | warning | The following assertion has been violated at time 0.000000 | | | | false assert | warning | Nominal variable violating max constraint: roo.irRadExc.J[7] <= 0.0, has value: 3350.12 assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not senCO2.warnAboutOnePortConnection assert | warning | Sensor Buildings.ThermalZones.Detailed.Examples.MixedAirCO2.senCO2 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in Buildings.ThermalZones.Detailed.Examples.MixedAirCO2.senCO2. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0955846s reading init.xml | | | | | | 0.00842734s reading info.xml | | | | | | 0.000196378s [ 0.1%] pre-initialization | | | | | | 0.0319104s [ 10.2%] initialization | | | | | | 2.7271e-05s [ 0.0%] steps | | | | | | 0.00581241s [ 1.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00133176s [ 0.4%] event-handling | | | | | | 0.0134014s [ 4.3%] overhead | | | | | | 0.26027s [ 83.2%] simulation | | | | | | 0.312949s [100.0%] total | | | | | events | | | | | | 3 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1000 steps taken | | | | | | 1555 calls of functionODE | | | | | | 166 evaluations of jacobian | | | | | | 97 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0448632s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.