Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSteadyStateTransient.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo", uses=false) Using package Buildings with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo) Running command: translateModel(Buildings.HeatTransfer.Examples.ConductorSteadyStateTransient,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSteadyStateTransient") translateModel(Buildings.HeatTransfer.Examples.ConductorSteadyStateTransient,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSteadyStateTransient") [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:257:38-257:110:writable] Warning: The file was not encoded in UTF-8: "

An important practical aspect of state machines is the abilit...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:761:36-761:108:writable] Warning: The file was not encoded in UTF-8: "

The Modelica_StateGraph2 library is described in detail in (O...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:1435:36-1435:108:writable] Warning: The file was not encoded in UTF-8: "

Main Authors:
SCode: time 0.1931/0.1943, allocations: 82.22 MB / 0.5941 GB, free: 5.59 MB / 446.1 MB Notification: Performance of NFInst.instantiate(Buildings.HeatTransfer.Examples.ConductorSteadyStateTransient): time 0.005516/0.1999, allocations: 4.304 MB / 0.5983 GB, free: 1.258 MB / 446.1 MB Notification: Performance of NFInst.instExpressions: time 0.005541/0.2055, allocations: 2.985 MB / 0.6012 GB, free: 14.26 MB / 462.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0008797/0.2064, allocations: 15.94 kB / 0.6012 GB, free: 14.24 MB / 462.1 MB Notification: Performance of NFTyping.typeComponents: time 0.001708/0.2081, allocations: 461.6 kB / 0.6017 GB, free: 13.79 MB / 462.1 MB Notification: Performance of NFTyping.typeBindings: time 0.001599/0.2097, allocations: 429.5 kB / 0.6021 GB, free: 13.37 MB / 462.1 MB Notification: Performance of NFTyping.typeClassSections: time 0.001593/0.2114, allocations: 449.5 kB / 0.6025 GB, free: 12.93 MB / 462.1 MB Notification: Performance of NFFlatten.flatten: time 0.003486/0.2149, allocations: 2.638 MB / 0.6051 GB, free: 10.29 MB / 462.1 MB Notification: Performance of NFFlatten.resolveConnections: time 0.0004944/0.2154, allocations: 256.4 kB / 0.6053 GB, free: 10.02 MB / 462.1 MB Notification: Performance of NFEvalConstants.evaluate: time 0.001594/0.217, allocations: 0.7396 MB / 0.6061 GB, free: 9.281 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/HeatTransfer/Conduction/BaseClasses/temperature_u.mo:9:41-9:55:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/HeatTransfer/Conduction/BaseClasses/temperature_u.mo:9:3-10:46:writable] Error: Non-array modification ‘"kg.K2/J"‘ for array component ‘unit‘, possibly due to missing ‘each‘. Notification: Performance of FrontEnd: time 0.0014/0.2184, allocations: 0.7274 MB / 0.6068 GB, free: 8.551 MB / 462.1 MB