Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo", uses=false) Using package Buildings with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo) Running command: translateModel(Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM") translateModel(Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM") [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:257:38-257:110:writable] Warning: The file was not encoded in UTF-8: "

An important practical aspect of state machines is the abilit...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:761:36-761:108:writable] Warning: The file was not encoded in UTF-8: "

The Modelica_StateGraph2 library is described in detail in (O...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:1435:36-1435:108:writable] Warning: The file was not encoded in UTF-8: "

Main Authors:
SCode: time 0.1893/0.1901, allocations: 82.22 MB / 0.5941 GB, free: 5.574 MB / 446.1 MB Notification: Performance of NFInst.instantiate(Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM): time 0.005225/0.1954, allocations: 4.044 MB / 0.598 GB, free: 1.5 MB / 446.1 MB Notification: Performance of NFInst.instExpressions: time 0.005288/0.2007, allocations: 2.731 MB / 0.6007 GB, free: 14.76 MB / 462.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0008056/0.2015, allocations: 15.94 kB / 0.6007 GB, free: 14.74 MB / 462.1 MB Notification: Performance of NFTyping.typeComponents: time 0.001248/0.2028, allocations: 306.4 kB / 0.601 GB, free: 14.44 MB / 462.1 MB Notification: Performance of NFTyping.typeBindings: time 0.001445/0.2043, allocations: 397.7 kB / 0.6014 GB, free: 14.05 MB / 462.1 MB Notification: Performance of NFTyping.typeClassSections: time 0.001356/0.2056, allocations: 443.1 kB / 0.6018 GB, free: 13.62 MB / 462.1 MB Notification: Performance of NFFlatten.flatten: time 0.002509/0.2082, allocations: 1.804 MB / 0.6036 GB, free: 11.81 MB / 462.1 MB Notification: Performance of NFFlatten.resolveConnections: time 0.0003917/0.2086, allocations: 162.5 kB / 0.6037 GB, free: 11.64 MB / 462.1 MB Notification: Performance of NFEvalConstants.evaluate: time 0.001212/0.2098, allocations: 0.4942 MB / 0.6042 GB, free: 11.15 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/HeatTransfer/Conduction/BaseClasses/temperature_u.mo:9:41-9:55:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/HeatTransfer/Conduction/BaseClasses/temperature_u.mo:9:3-10:46:writable] Error: Non-array modification ‘"kg.K2/J"‘ for array component ‘unit‘, possibly due to missing ‘each‘. Notification: Performance of FrontEnd: time 0.001148/0.211, allocations: 0.5836 MB / 0.6048 GB, free: 10.56 MB / 462.1 MB