Environment - simulationEnvironment: startTime=0 stopTime=200 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.08 Regular simulation: ./Buildings_11_Buildings.Fluid.Movers.Validation.PowerEuler -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pump_dp.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning in Buildings.Fluid.Movers.Validation.PowerEuler.pump_dp: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | *** Warning in Buildings.Fluid.Movers.Validation.PowerEuler.pump_dp: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pump_m_flow.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning in Buildings.Fluid.Movers.Validation.PowerEuler.pump_m_flow: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | *** Warning in Buildings.Fluid.Movers.Validation.PowerEuler.pump_m_flow: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0202457s reading init.xml | | | | | | 0.00222971s reading info.xml | | | | | | 0.00111826s [ 3.0%] pre-initialization | | | | | | 0.00130708s [ 3.5%] initialization | | | | | | 3.436e-06s [ 0.0%] steps | | | | | | 0.000763913s [ 2.0%] solver (excl. callbacks) | | | | | | 0.00241817s [ 6.4%] creating output-file | | | | | | 0.000358771s [ 1.0%] event-handling | | | | | | 0.0113755s [ 30.3%] overhead | | | | | | 0.0202446s [ 53.9%] simulation | | | | | | 0.0375897s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 72 steps taken | | | | | | 89 calls of functionODE | | | | | | 57 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000112469s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.