Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-08 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_11_Buildings.Fluid.HeatPumps.ModularReversible.Examples.LargeScaleWaterToWater_OneRoomRadiator -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS assert | warning | The following assertion has been violated at time 0.000000 | | | | heaPum.eff.PEleMin >= 1e-15 assert | warning | Variable violating min constraint: 1e-15 <= heaPum.eff.PEleMin, has value: -1158.29 assert | warning | The following assertion has been violated at time 0.000000 | | | | heaPum.eff.invXReg.delta >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= heaPum.eff.invXReg.delta, has value: -1158.29 assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pumHeaPumSou.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning in Buildings.Fluid.HeatPumps.ModularReversible.Examples.LargeScaleWaterToWater_OneRoomRadiator.pumHeaPumSou: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | 7.3838 <= heaPum.refCyc.refCycHeaPumHea.mCon_flow_max assert | warning | In Buildings.Fluid.HeatPumps.ModularReversible.Examples.LargeScaleWaterToWater_OneRoomRadiator.heaPum.refCyc.refCycHeaPumHea: The nominal condenser mass flow rate (7.3838 kg/s) is bigger than the | | | | maximal value (-0.140152 kg/s) for the table data | | | | when assuming a temperature spread between 3 and 10 K, as in EN 14511. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | 7.6823 <= heaPum.refCyc.refCycHeaPumHea.mEva_flow_max assert | warning | In Buildings.Fluid.HeatPumps.ModularReversible.Examples.LargeScaleWaterToWater_OneRoomRadiator.heaPum.refCyc.refCycHeaPumHea: The nominal evaporator mass flow rate (7.6823 kg/s) is bigger than the | | | | maximal value (-0.125106 kg/s) for the table data | | | | when assuming a temperature spread between 3 and 10 K, as in EN 14511. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | 7.3838 >= heaPum.refCyc.refCycHeaPumCoo.mCon_flow_min assert | warning | In Buildings.Fluid.HeatPumps.ModularReversible.Examples.LargeScaleWaterToWater_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo: The nominal condenser mass flow rate (7.3838 kg/s) is smaller than the | | | | minimal value (9.30435 kg/s) for the table data | | | | when assuming a temperature spread between 3 and 10 K, as in EN 14511. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | heaPum.eff.PEleMin > 0.0 assert | error | In Buildings.Fluid.HeatPumps.ModularReversible.Examples.LargeScaleWaterToWater_OneRoomRadiator.heaPum.eff: PEleMin must be greater than zero. Disable efficiency calculation using | | | | calEff=false to debug why PEle_nominal is lower than zero. assert | info | simulation terminated by an assertion at initialization