Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_10_Buildings.Fluid.HeatExchangers.Examples.WaterHeater_T -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Buildings.Fluid.HeatExchangers.Examples.WaterHeater_T.mov: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | mov.per.haveWMot_nominal or not (mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Buildings.Fluid.HeatExchangers.Examples.WaterHeater_T.mov: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00991604s reading init.xml | | | | | | 0.000931457s reading info.xml | | | | | | 0.000526337s [ 2.1%] pre-initialization | | | | | | 0.000342732s [ 1.4%] initialization | | | | | | 1.813e-06s [ 0.0%] steps | | | | | | 0.00187991s [ 7.5%] solver (excl. callbacks) | | | | | | 0.00168885s [ 6.8%] creating output-file | | | | | | 0.000560438s [ 2.2%] event-handling | | | | | | 0.00724732s [ 29.1%] overhead | | | | | | 0.0126805s [ 50.9%] simulation | | | | | | 0.0249279s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1244 steps taken | | | | | | 1994 calls of functionODE | | | | | | 429 evaluations of jacobian | | | | | | 133 error test failures | | | | | | 10 convergence test failures | | | | | | 0.00141303s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.