Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_1.6_Buildings.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACNoExhaust -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Buildings.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACNoExhaust.mov: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | mov.per.haveWMot_nominal or not (mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Buildings.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACNoExhaust.mov: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0160303s reading init.xml | | | | | | 0.00136266s reading info.xml | | | | | | 0.000144301s [ 0.6%] pre-initialization | | | | | | 0.000356559s [ 1.5%] initialization | | | | | | 2.334e-06s [ 0.0%] steps | | | | | | 0.00207892s [ 8.8%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000591182s [ 2.5%] event-handling | | | | | | 0.00478124s [ 20.3%] overhead | | | | | | 0.0155629s [ 66.2%] simulation | | | | | | 0.0235174s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1949 steps taken | | | | | | 2654 calls of functionODE | | | | | | 362 evaluations of jacobian | | | | | | 120 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000977898s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.