Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo", uses=false) Using package BuildSysPro with version 3.5.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler,tolerance=1e-06,outputFormat="empty",numberOfIntervals=16,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler") translateModel(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler,tolerance=1e-06,outputFormat="empty",numberOfIntervals=16,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0007971/0.0007967, allocations: 98.27 kB / 15.36 MB, free: 0.7344 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.005041/0.005041, allocations: 172 kB / 16.27 MB, free: 6.367 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.114/1.114, allocations: 223.3 MB / 240.3 MB, free: 5.246 MB / 190.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/Building/BuildingEnvelope/HeatTransfer/package.mo:2:1-40:17:writable] Warning: Soil_case_nappe was referenced in the package.order file, but was not found in package.mo, Soil_case_nappe/package.mo or Soil_case_nappe.mo. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo): time 0.8051/0.8051, allocations: 143.2 MB / 434.6 MB, free: 13.57 MB / 350.1 MB Notification: Performance of FrontEnd - loaded program: time 0.0002514/0.0002515, allocations: 4 kB / 0.5164 GB, free: 11.14 MB / 430.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1199/0.1202, allocations: 83.42 MB / 0.5978 GB, free: 7.691 MB / 0.4981 GB Notification: Performance of NFInst.instantiate(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler): time 0.001928/0.1221, allocations: 1.993 MB / 0.5998 GB, free: 5.684 MB / 0.4981 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/BaseClasses/Media/OLD_THERMHYGAERO/AirFunctions/Psat.mo:3:3-3:24:writable] Error: Invalid public variable AH, function variables that are not input/output must be protected. Notification: Performance of FrontEnd: time 0.0007169/0.1229, allocations: 0.4908 MB / 0.6003 GB, free: 5.191 MB / 0.4981 GB