Environment - simulationEnvironment: startTime=0 stopTime=500 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.2 Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Fluid.HeatExchangers.ActiveBeams.Validation.NumberOfBeamsDynamics -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (pumHotWat.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumHotWat.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in BuildSysPro.IBPSA.Fluid.HeatExchangers.ActiveBeams.Validation.NumberOfBeamsDynamics.pumHotWat: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pumHotWat.per.haveWMot_nominal or not (pumHotWat.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumHotWat.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in BuildSysPro.IBPSA.Fluid.HeatExchangers.ActiveBeams.Validation.NumberOfBeamsDynamics.pumHotWat: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (pumChiWat.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumChiWat.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in BuildSysPro.IBPSA.Fluid.HeatExchangers.ActiveBeams.Validation.NumberOfBeamsDynamics.pumChiWat: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pumChiWat.per.haveWMot_nominal or not (pumChiWat.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumChiWat.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in BuildSysPro.IBPSA.Fluid.HeatExchangers.ActiveBeams.Validation.NumberOfBeamsDynamics.pumChiWat: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (pumHotWat10.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumHotWat10.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in BuildSysPro.IBPSA.Fluid.HeatExchangers.ActiveBeams.Validation.NumberOfBeamsDynamics.pumHotWat10: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pumHotWat10.per.haveWMot_nominal or not (pumHotWat10.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumHotWat10.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in BuildSysPro.IBPSA.Fluid.HeatExchangers.ActiveBeams.Validation.NumberOfBeamsDynamics.pumHotWat10: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (pumChiWat10.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumChiWat10.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in BuildSysPro.IBPSA.Fluid.HeatExchangers.ActiveBeams.Validation.NumberOfBeamsDynamics.pumChiWat10: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pumChiWat10.per.haveWMot_nominal or not (pumChiWat10.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumChiWat10.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in BuildSysPro.IBPSA.Fluid.HeatExchangers.ActiveBeams.Validation.NumberOfBeamsDynamics.pumChiWat10: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0376646s reading init.xml | | | | | | 0.00419835s reading info.xml | | | | | | 0.000168767s [ 0.5%] pre-initialization | | | | | | 0.000526297s [ 1.4%] initialization | | | | | | 6.843e-06s [ 0.0%] steps | | | | | | 0.00187735s [ 5.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00322711s [ 8.7%] event-handling | | | | | | 0.0126709s [ 34.1%] overhead | | | | | | 0.0187003s [ 50.3%] simulation | | | | | | 0.0371776s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 105 steps taken | | | | | | 122 calls of functionODE | | | | | | 52 evaluations of jacobian | | | | | | 1 error test failures | | | | | | 0 convergence test failures | | | | | | 3.8793e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.