Environment - simulationEnvironment: startTime=0 stopTime=29600 tolerance=1e-06 numberOfIntervals=29600 stepSize=1 Regular simulation: ./AixLib_latest_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.StaticValidation -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "Boundary" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationEta.txt" stdout | info | ... loading "Boundary" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationOda.txt" stdout | info | ... loading "Result" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationResult.txt" assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | fan.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | fan1.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | The following assertion has been violated at time 4810.500000 | | | | enthalpyExchanger.airDuct1.senRelHum.phi >= 0.01 and enthalpyExchanger.airDuct1.senRelHum.phi <= 0.99 assert | info | Variable violating min/max constraint: 0.01 <= enthalpyExchanger.airDuct1.senRelHum.phi <= 0.99, has value: 0.991497 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.10719s reading init.xml | | | | | | 0.00955196s reading info.xml | | | | | | 0.000908624s [ 0.0%] pre-initialization | | | | | | 0.00257721s [ 0.0%] initialization | | | | | | 0.000141055s [ 0.0%] steps | | | | | | 0.277334s [ 1.7%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0539689s [ 0.3%] event-handling | | | | | | 0.489795s [ 3.0%] overhead | | | | | | 15.6869s [ 95.0%] simulation | | | | | | 16.5117s [100.0%] total | | | | | events | | | | | | 72 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 7406 steps taken | | | | | | 10238 calls of functionODE | | | | | | 1176 evaluations of jacobian | | | | | | 224 error test failures | | | | | | 3 convergence test failures | | | | | | 3.63096s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.