Environment - simulationEnvironment: startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=3600 stepSize=2 Regular simulation: ./AixLib_latest_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.DynamicValidation -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "Boundary" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Resources/Fluid/MembraneBasedEnthalpyExchanger/DynamicValidationEta.txt" stdout | info | ... loading "Boundary" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Resources/Fluid/MembraneBasedEnthalpyExchanger/DynamicValidationOda.txt" stdout | info | ... loading "Result" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Resources/Fluid/MembraneBasedEnthalpyExchanger/DynamicValidationResult.txt" assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | fan.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | fan1.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0997512s reading init.xml | | | | | | 0.00982533s reading info.xml | | | | | | 0.000701536s [ 0.0%] pre-initialization | | | | | | 0.010907s [ 0.0%] initialization | | | | | | 0.000149491s [ 0.0%] steps | | | | | | 0.960757s [ 3.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.318499s [ 1.0%] event-handling | | | | | | 0.0746468s [ 0.2%] overhead | | | | | | 30.3645s [ 95.7%] simulation | | | | | | 31.7302s [100.0%] total | | | | | events | | | | | | 676 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 21202 steps taken | | | | | | 31983 calls of functionODE | | | | | | 7952 evaluations of jacobian | | | | | | 1515 error test failures | | | | | | 1 convergence test failures | | | | | | 24.7141s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.