Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./AixLib_latest_AixLib.Fluid.FMI.Validation.HeaterFan_noReverseFlow -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00734223s reading init.xml | | | | | | 0.000742673s reading info.xml | | | | | | 0.000105718s [ 1.6%] pre-initialization | | | | | | 0.000180839s [ 2.8%] initialization | | | | | | 4.61e-07s [ 0.0%] steps | | | | | | 5.3529e-05s [ 0.8%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.7732e-05s [ 0.3%] event-handling | | | | | | 0.0026565s [ 40.7%] overhead | | | | | | 0.0035163s [ 53.8%] simulation | | | | | | 0.00653108s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 5000 steps taken | | | | | | 5000 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.