Environment - simulationEnvironment: startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=2500 stepSize=2.88 Regular simulation: ./AixLib_AixLib.Systems.ModularAHU.Examples.GenericAHU -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | genericAHU.fanSup.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | genericAHU.fanRet.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | The following assertion has been violated at time 2.880000 | | | | genericAHU.preheater.hydraulicModule.valve.y_actual >= 0.0 and genericAHU.preheater.hydraulicModule.valve.y_actual <= 1.0 assert | info | Variable violating min/max constraint: 0.0 <= genericAHU.preheater.hydraulicModule.valve.y_actual <= 1.0, has value: -5.17252e-22 assert | info | The following assertion has been violated at time 10.080000 | | | | genericAHU.cooler.hydraulicModule.valve.y_actual >= 0.0 and genericAHU.cooler.hydraulicModule.valve.y_actual <= 1.0 assert | info | Variable violating min/max constraint: 0.0 <= genericAHU.cooler.hydraulicModule.valve.y_actual <= 1.0, has value: -1.71249e-21 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.205605s reading init.xml | | | | | | 0.0234894s reading info.xml | | | | | | 0.000630523s [ 0.1%] pre-initialization | | | | | | 0.00191503s [ 0.3%] initialization | | | | | | 0.000101751s [ 0.0%] steps | | | | | | 0.0400024s [ 5.3%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000379688s [ 0.1%] event-handling | | | | | | 0.0836056s [ 11.0%] overhead | | | | | | 0.631082s [ 83.3%] simulation | | | | | | 0.757717s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 409 steps taken | | | | | | 626 calls of functionODE | | | | | | 65 evaluations of jacobian | | | | | | 17 error test failures | | | | | | 4 convergence test failures | | | | | | 0.0466448s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.