/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.ElementTwoPhase_res.mat --tempDir=temp_ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_ElementTwoPhase_fmu --startTime=0 --stopTime=60 --timeout=1200 --tolerance=1e-06 ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_ElementTwoPhase.fmu info: maximum step size for 'model.root': 0.001000 info: Result file: ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.ElementTwoPhase_res.mat (bufferSize=1) warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.ElementTwoPhase/temp_ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_ElementTwoPhase_fmu/model-fbbitlg8/temp/0001_ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_ElementTwoPhase (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.1.0-main/Boundaries/Internal/PartialVolume.mo:110: The following assertion has been violated at time 0.000000 flowResistance1.inlet.m_flow > volume.m_flow_assert assert | warning | Negative massflow at Volume inlet warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.ElementTwoPhase/temp_ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_ElementTwoPhase_fmu/model-fbbitlg8/temp/0001_ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_ElementTwoPhase (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.1.0-main/Boundaries/Internal/PartialVolume.mo:110: The following assertion has been violated at time 0.000000 flowResistance3.inlet.m_flow > volume1.m_flow_assert assert | warning | Negative massflow at Volume inlet warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.ElementTwoPhase/temp_ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_ElementTwoPhase_fmu/model-fbbitlg8/temp/0001_ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_ElementTwoPhase (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.1.0-main/Boundaries/Internal/PartialVolume.mo:111: The following assertion has been violated at time 0.001000 mCV2.inlet.m_flow > volume.m_flow_assert assert | warning | Positive massflow at Volume outlet warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.ElementTwoPhase/temp_ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_ElementTwoPhase_fmu/model-fbbitlg8/temp/0001_ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_ElementTwoPhase (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.1.0-main/Boundaries/Internal/PartialVolume.mo:111: The following assertion has been violated at time 0.001000 mCV3.inlet.m_flow > volume1.m_flow_assert assert | warning | Positive massflow at Volume outlet assert | debug | memory_pool.c: Error: Failed to allocate memory (calloc returned NULL.) error: [operator()] Timeout occurred during simulation info: 4 warnings info: 1 errors info: Final Statistics for 'model.root': NumSteps = 452 NumRhsEvals = 677 NumLinSolvSetups = 180 NumNonlinSolvIters = 675 NumNonlinSolvConvFails = 0 NumErrTestFails = 63