OMSimulator --tempDir=temp_ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed_fmu --startTime=0 --stopTime=5 --timeout=50 --tolerance=1e-06 ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed.fmu assert | debug | ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed_functions.c:1355: Invalid root: (-39.8788)^(0.284743) assert | debug | ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed_functions.c:1355: Invalid root: (-12.747)^(0.284743) info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed.Compressor1.Eta.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed.Compressor1.Eta.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed.Compressor1.Phic.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed.Compressor1.Phic.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed.Compressor1.PressRatio.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed.Compressor1.PressRatio.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed.Compressor1.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed.Turbine1.Eta.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed.Turbine1.Eta.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed.Turbine1.Phic.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed.Turbine1.Phic.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ThermoPower_ThermoPower_Test_GasComponents_TestTurboJetConstSpeed.Turbine1.fileName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 5001 NumRhsEvals = 5002 NumLinSolvSetups = 251 NumNonlinSolvIters = 5001 NumNonlinSolvConvFails = 0 NumErrTestFails = 0