/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Modelica_trunk_Modelica.Fluid.Examples.PumpingSystem_res.mat --tempDir=temp_Modelica_trunk_Modelica_Fluid_Examples_PumpingSystem_fmu --startTime=0 --stopTime=2000 --timeout=50 --tolerance=1e-06 Modelica_trunk_Modelica_Fluid_Examples_PumpingSystem.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_trunk_Modelica.Fluid.Examples.PumpingSystem/temp_Modelica_trunk_Modelica_Fluid_Examples_PumpingSystem_fmu/model-5fd7z9ko/temp/0001_Modelica_trunk_Modelica_Fluid_Examples_PumpingSystem (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Fluid/Interfaces.mo:1027: The following assertion has been violated at time 0.000000 pipe.flowModel.m_flows[1] >= 0.0 and pipe.flowModel.m_flows[1] <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= pipe.flowModel.m_flows[1] <= 100000.0, has value: -141.424 info: maximum step size for 'model.root': 0.001000 info: Result file: Modelica_trunk_Modelica.Fluid.Examples.PumpingSystem_res.mat (bufferSize=1) assert | debug | memory_pool.c: Error: Failed to allocate memory (calloc returned NULL.) error: [operator()] Timeout occurred during simulation info: 1 warnings info: 1 errors info: Final Statistics for 'model.root': NumSteps = 84943 NumRhsEvals = 84991 NumLinSolvSetups = 4272 NumNonlinSolvIters = 84990 NumNonlinSolvConvFails = 0 NumErrTestFails = 8