OMSimulator --tempDir=temp_IDEAS_IDEAS_Buildings_Components_InterzonalAirFlow_Examples_InterzonalAirFlow_fmu --startTime=0 --stopTime=1e+06 --timeout=50 --tolerance=1e-06 IDEAS_IDEAS_Buildings_Components_InterzonalAirFlow_Examples_InterzonalAirFlow.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Buildings.Components.InterzonalAirFlow.Examples.InterzonalAirFlow/temp_IDEAS_IDEAS_Buildings_Components_InterzonalAirFlow_Examples_InterzonalAirFlow_fmu/model-8xeuhkt0/temp/0001_IDEAS_IDEAS_Buildings_Components_InterzonalAirFlow_Examples_InterzonalAirFlow (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Interfaces/LumpedVolumeDeclarations.mo:47: The following assertion has been violated at time 0.000000 zoneAirTightN50.airModel.vol.dynBal.mSenFac >= 1.0 assert | warning | Variable violating min constraint: 1.0 <= zoneAirTightN50.airModel.vol.dynBal.mSenFac, has value: 0.822 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Buildings.Components.InterzonalAirFlow.Examples.InterzonalAirFlow/temp_IDEAS_IDEAS_Buildings_Components_InterzonalAirFlow_Examples_InterzonalAirFlow_fmu/model-8xeuhkt0/temp/0001_IDEAS_IDEAS_Buildings_Components_InterzonalAirFlow_Examples_InterzonalAirFlow (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Interfaces/LumpedVolumeDeclarations.mo:47: The following assertion has been violated at time 0.000000 zoneFixedPressureN50.airModel.vol.dynBal.mSenFac >= 1.0 assert | warning | Variable violating min constraint: 1.0 <= zoneFixedPressureN50.airModel.vol.dynBal.mSenFac, has value: 0.822 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Buildings.Components.InterzonalAirFlow.Examples.InterzonalAirFlow/temp_IDEAS_IDEAS_Buildings_Components_InterzonalAirFlow_Examples_InterzonalAirFlow_fmu/model-8xeuhkt0/temp/0001_IDEAS_IDEAS_Buildings_Components_InterzonalAirFlow_Examples_InterzonalAirFlow (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Interfaces/LumpedVolumeDeclarations.mo:47: The following assertion has been violated at time 0.000000 zoneFixedPressure.airModel.vol.dynBal.mSenFac >= 1.0 assert | warning | Variable violating min constraint: 1.0 <= zoneFixedPressure.airModel.vol.dynBal.mSenFac, has value: 0.822 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Buildings.Components.InterzonalAirFlow.Examples.InterzonalAirFlow/temp_IDEAS_IDEAS_Buildings_Components_InterzonalAirFlow_Examples_InterzonalAirFlow_fmu/model-8xeuhkt0/temp/0001_IDEAS_IDEAS_Buildings_Components_InterzonalAirFlow_Examples_InterzonalAirFlow (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Interfaces/LumpedVolumeDeclarations.mo:47: The following assertion has been violated at time 0.000000 zoneAirTight.airModel.vol.dynBal.mSenFac >= 1.0 assert | warning | Variable violating min constraint: 1.0 <= zoneAirTight.airModel.vol.dynBal.mSenFac, has value: 0.822 info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) error: [operator()] Timeout occurred during simulation info: 4 warnings info: 1 errors info: Final Statistics for 'model.root': NumSteps = 35590 NumRhsEvals = 35591 NumLinSolvSetups = 1781 NumNonlinSolvIters = 35590 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 [CVODE ERROR] CVode cvode_mem = NULL illegal. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -21