OMSimulator --tempDir=temp_IDEAS_IDEAS_Buildings_Components_Examples_WindowThermalBridge_fmu --startTime=0 --stopTime=1e+06 --timeout=50 --tolerance=1e-06 IDEAS_IDEAS_Buildings_Components_Examples_WindowThermalBridge.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Buildings.Components.Examples.WindowThermalBridge/temp_IDEAS_IDEAS_Buildings_Components_Examples_WindowThermalBridge_fmu/model-3e86zfu7/temp/0001_IDEAS_IDEAS_Buildings_Components_Examples_WindowThermalBridge (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneInterface.mo:91: The following assertion has been violated during initialization at time 0.000000 false assert | warning | In IDEAS.Buildings.Components.Examples.WindowThermalBridge.zone: You have made connections to port_a or port_b. These connectors will be | | | | removed in a future release of IDEAS. Use the connector `ports' instead. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Buildings.Components.Examples.WindowThermalBridge/temp_IDEAS_IDEAS_Buildings_Components_Examples_WindowThermalBridge_fmu/model-3e86zfu7/temp/0001_IDEAS_IDEAS_Buildings_Components_Examples_WindowThermalBridge (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/BaseClasses/RadiativeHeatTransfer/ZoneLwDistribution.mo:84: The following assertion has been violated during initialization at time 0.000000 max(zone.radDistrLw.F1) < zone.radDistrLw.FMax * 0.9 and zone.radDistrLw.computeCarroll or zone.radDistrLw.simVieFac assert | warning | WARNING: In IDEAS.Buildings.Components.Examples.WindowThermalBridge.zone.radDistrLw: The computed view factor returned unexpected results. | | | | A simplified method is used. | | | | This may be caused by trying to model a non-physical geometry. | | | | Avoid this warning by setting simVieFac=true in the respective zone model. info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) error: [operator()] Timeout occurred during simulation info: 2 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Buildings.Components.Examples.WindowThermalBridge/temp_IDEAS_IDEAS_Buildings_Components_Examples_WindowThermalBridge_fmu/model-3e86zfu7/temp/0001_IDEAS_IDEAS_Buildings_Components_Examples_WindowThermalBridge (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [updateInputs] fmi2_setTime failed for FMU "model.root.IDEAS_IDEAS_Buildings_Components_Examples_WindowThermalBridge"