Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.Geothermal.Borefields.BaseClasses.Boreholes.BaseClasses.Functions.Validation.InternalResistancesOneUTubeNegative.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.Boreholes.BaseClasses.Functions.Validation.InternalResistancesOneUTubeNegative,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.Boreholes.BaseClasses.Functions.Validation.InternalResistancesOneUTubeNegative,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.408/1.408, allocations: 252 MB / 267.3 MB, free: 10.85 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001182/0.001182, allocations: 182.7 kB / 327 MB, free: 2.133 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.851/1.851, allocations: 205.4 MB / 0.578 GB, free: 20.12 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008017/0.0008018, allocations: 89.44 kB / 0.6826 GB, free: 12.76 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0003703/0.0003704, allocations: 9 kB / 0.7971 GB, free: 135.2 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2377/0.2381, allocations: 106.3 MB / 0.901 GB, free: 63.35 MB / 0.6042 GB Notification: Performance of NFInst.instantiate(Buildings.Fluid.Geothermal.Borefields.BaseClasses.Boreholes.BaseClasses.Functions.Validation.InternalResistancesOneUTubeNegative): time 0.00153/0.2397, allocations: 1.166 MB / 0.9021 GB, free: 62.17 MB / 0.6042 GB Notification: Performance of NFInst.instExpressions: time 0.004113/0.2438, allocations: 2.986 MB / 0.905 GB, free: 59.17 MB / 0.6042 GB Notification: Performance of NFInst.updateImplicitVariability: time 4.834e-05/0.2439, allocations: 0 / 0.905 GB, free: 59.17 MB / 0.6042 GB Notification: Performance of NFTyping.typeComponents: time 2.605e-05/0.244, allocations: 0 / 0.905 GB, free: 59.17 MB / 0.6042 GB Notification: Performance of NFTyping.typeBindings: time 7.281e-05/0.244, allocations: 19.84 kB / 0.905 GB, free: 59.15 MB / 0.6042 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Geothermal/Borefields/BaseClasses/Boreholes/BaseClasses/Functions/internalResistancesOneUTube.mo:2:1-155:32:writable] Warning: Pure function ‘Buildings.Fluid.Geothermal.Borefields.BaseClasses.Boreholes.BaseClasses.Functions.internalResistancesOneUTube‘ contains a call to impure function ‘Modelica.Utilities.Streams.print‘. Notification: Performance of NFTyping.typeClassSections: time 0.003635/0.2477, allocations: 1.429 MB / 0.9064 GB, free: 57.74 MB / 0.6042 GB Notification: Performance of NFFlatten.flatten: time 6.792e-05/0.2478, allocations: 31.81 kB / 0.9065 GB, free: 57.71 MB / 0.6042 GB Notification: Performance of NFFlatten.resolveConnections: time 4.575e-05/0.2478, allocations: 7.938 kB / 0.9065 GB, free: 57.7 MB / 0.6042 GB Notification: Performance of NFEvalConstants.evaluate: time 2.911e-05/0.2479, allocations: 19.92 kB / 0.9065 GB, free: 57.68 MB / 0.6042 GB Notification: Performance of NFSimplifyModel.simplify: time 2.699e-05/0.2479, allocations: 15.88 kB / 0.9065 GB, free: 57.66 MB / 0.6042 GB Notification: Performance of NFPackage.collectConstants: time 9.969e-06/0.2479, allocations: 3.938 kB / 0.9065 GB, free: 57.66 MB / 0.6042 GB Notification: Performance of NFFlatten.collectFunctions: time 0.00219/0.2501, allocations: 1.439 MB / 0.9079 GB, free: 56.22 MB / 0.6042 GB Notification: Performance of NFScalarize.scalarize: time 2.017e-05/0.2501, allocations: 7.984 kB / 0.9079 GB, free: 56.21 MB / 0.6042 GB Notification: Performance of NFVerifyModel.verify: time 4.056e-05/0.2502, allocations: 41.58 kB / 0.908 GB, free: 56.16 MB / 0.6042 GB Notification: Performance of NFConvertDAE.convert: time 0.001951/0.2522, allocations: 1.104 MB / 0.909 GB, free: 55.06 MB / 0.6042 GB Notification: Performance of FrontEnd - DAE generated: time 6.772e-06/0.2522, allocations: 4 kB / 0.909 GB, free: 55.05 MB / 0.6042 GB Notification: Performance of FrontEnd: time 2.024e-06/0.2522, allocations: 4 kB / 0.9091 GB, free: 55.05 MB / 0.6042 GB Notification: Performance of Transformations before backend: time 6.162e-06/0.2522, allocations: 0 / 0.9091 GB, free: 55.05 MB / 0.6042 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 0 * Number of variables: 0 Notification: Performance of Generate backend data structure: time 0.0006307/0.2528, allocations: 0.5092 MB / 0.9095 GB, free: 54.5 MB / 0.6042 GB Notification: Performance of prepare preOptimizeDAE: time 5.044e-05/0.2529, allocations: 8.031 kB / 0.9096 GB, free: 54.49 MB / 0.6042 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 3.249e-05/0.2529, allocations: 110 kB / 0.9097 GB, free: 54.37 MB / 0.6042 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 5.154e-05/0.253, allocations: 76.22 kB / 0.9097 GB, free: 54.3 MB / 0.6042 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.0001046/0.2531, allocations: 255.5 kB / 0.91 GB, free: 54.01 MB / 0.6042 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 2.865e-05/0.2531, allocations: 158.9 kB / 0.9101 GB, free: 53.85 MB / 0.6042 GB Notification: Performance of preOpt expandDerOperator (simulation): time 2.784e-05/0.2532, allocations: 154.9 kB / 0.9103 GB, free: 53.7 MB / 0.6042 GB Notification: Performance of preOpt clockPartitioning (simulation): time 4.969e-05/0.2532, allocations: 108.9 kB / 0.9104 GB, free: 53.59 MB / 0.6042 GB Notification: Performance of preOpt findStateOrder (simulation): time 1.319e-05/0.2532, allocations: 75.28 kB / 0.9105 GB, free: 53.51 MB / 0.6042 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 1.84e-05/0.2533, allocations: 150.6 kB / 0.9106 GB, free: 53.36 MB / 0.6042 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 2.235e-05/0.2533, allocations: 154.6 kB / 0.9107 GB, free: 53.21 MB / 0.6042 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 2.416e-05/0.2533, allocations: 158.6 kB / 0.9109 GB, free: 53.05 MB / 0.6042 GB Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.0002002/0.2535, allocations: 465.8 kB / 0.9113 GB, free: 52.55 MB / 0.6042 GB Notification: Performance of preOpt comSubExp (simulation): time 4.578e-05/0.2536, allocations: 169.1 kB / 0.9115 GB, free: 52.38 MB / 0.6042 GB Notification: Performance of preOpt resolveLoops (simulation): time 1.933e-05/0.2536, allocations: 80.14 kB / 0.9116 GB, free: 52.29 MB / 0.6042 GB Notification: Performance of preOpt evalFunc (simulation): time 1.178e-05/0.2536, allocations: 87.22 kB / 0.9117 GB, free: 52.21 MB / 0.6042 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 2.065e-05/0.2537, allocations: 105.8 kB / 0.9118 GB, free: 52.09 MB / 0.6042 GB Notification: Performance of pre-optimization done (n=0): time 1.152e-06/0.2537, allocations: 0 / 0.9118 GB, free: 52.09 MB / 0.6042 GB Notification: Performance of matching and sorting (n=0): time 6.837e-05/0.2537, allocations: 37.62 kB / 0.9118 GB, free: 52.05 MB / 0.6042 GB Notification: Performance of inlineWhenForInitialization (initialization): time 2.868e-05/0.2538, allocations: 126.7 kB / 0.9119 GB, free: 51.91 MB / 0.6042 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.0001145/0.2539, allocations: 136.4 kB / 0.912 GB, free: 51.77 MB / 0.6042 GB Notification: Performance of collectPreVariables (initialization): time 7.494e-06/0.2539, allocations: 29.7 kB / 0.9121 GB, free: 51.74 MB / 0.6042 GB Notification: Performance of collectInitialEqns (initialization): time 3.004e-05/0.2539, allocations: 84.14 kB / 0.9122 GB, free: 51.65 MB / 0.6042 GB Notification: Performance of collectInitialBindings (initialization): time 2.595e-06/0.254, allocations: 0 / 0.9122 GB, free: 51.65 MB / 0.6042 GB Notification: Performance of simplifyInitialFunctions (initialization): time 3.527e-06/0.254, allocations: 4 kB / 0.9122 GB, free: 51.65 MB / 0.6042 GB Notification: Performance of setup shared object (initialization): time 4.589e-05/0.254, allocations: 318.8 kB / 0.9125 GB, free: 51.33 MB / 0.6042 GB Notification: Performance of preBalanceInitialSystem (initialization): time 2.064e-05/0.254, allocations: 4 kB / 0.9125 GB, free: 51.32 MB / 0.6042 GB Notification: Performance of partitionIndependentBlocks (initialization): time 1.479e-05/0.2541, allocations: 8 kB / 0.9125 GB, free: 51.32 MB / 0.6042 GB Notification: Performance of analyzeInitialSystem (initialization): time 3.734e-05/0.2541, allocations: 8.859 kB / 0.9125 GB, free: 51.3 MB / 0.6042 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 2.314e-06/0.2541, allocations: 0 / 0.9125 GB, free: 51.3 MB / 0.6042 GB Notification: Performance of matching and sorting (n=4) (initialization): time 0.000115/0.2542, allocations: 57.59 kB / 0.9125 GB, free: 51.24 MB / 0.6042 GB Notification: Performance of prepare postOptimizeDAE: time 1.417e-05/0.2543, allocations: 11.94 kB / 0.9126 GB, free: 51.23 MB / 0.6042 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 1.727e-05/0.2543, allocations: 0 / 0.9126 GB, free: 51.23 MB / 0.6042 GB Notification: Performance of postOpt tearingSystem (initialization): time 1.075e-05/0.2543, allocations: 0 / 0.9126 GB, free: 51.23 MB / 0.6042 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 1.002e-06/0.2543, allocations: 48 / 0.9126 GB, free: 51.23 MB / 0.6042 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 4.739e-06/0.2543, allocations: 4 kB / 0.9126 GB, free: 51.23 MB / 0.6042 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 2.317e-05/0.2543, allocations: 7.891 kB / 0.9126 GB, free: 51.22 MB / 0.6042 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 7.524e-06/0.2543, allocations: 0 / 0.9126 GB, free: 51.22 MB / 0.6042 GB Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 1 * Number of states: 0 () * Number of discrete variables: 0 () * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1): * Single equations (assignments): 0 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 1 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 Notification: Performance of prepare postOptimizeDAE: time 6.05e-05/0.2544, allocations: 191.3 kB / 0.9127 GB, free: 51.02 MB / 0.6042 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 4.077e-05/0.2545, allocations: 108.9 kB / 0.9128 GB, free: 50.91 MB / 0.6042 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 2.7e-05/0.2545, allocations: 116.8 kB / 0.913 GB, free: 50.79 MB / 0.6042 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 2.438e-05/0.2545, allocations: 176.3 kB / 0.9131 GB, free: 50.61 MB / 0.6042 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 2.862e-05/0.2546, allocations: 184.2 kB / 0.9133 GB, free: 50.42 MB / 0.6042 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 3.953e-05/0.2546, allocations: 184.2 kB / 0.9135 GB, free: 50.23 MB / 0.6042 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.0001379/0.2547, allocations: 421.3 kB / 0.9139 GB, free: 49.76 MB / 0.6042 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 1.429e-05/0.2548, allocations: 108.9 kB / 0.914 GB, free: 49.65 MB / 0.6042 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 1.735e-05/0.2548, allocations: 105 kB / 0.9141 GB, free: 49.54 MB / 0.6042 GB Notification: Performance of postOpt tearingSystem (simulation): time 2.844e-05/0.2548, allocations: 180.2 kB / 0.9143 GB, free: 49.36 MB / 0.6042 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 2.463e-05/0.2549, allocations: 176.3 kB / 0.9144 GB, free: 49.18 MB / 0.6042 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 2.254e-05/0.2549, allocations: 180.3 kB / 0.9146 GB, free: 48.99 MB / 0.6042 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 2.656e-05/0.2549, allocations: 192.2 kB / 0.9148 GB, free: 48.8 MB / 0.6042 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 6.795e-05/0.255, allocations: 311.6 kB / 0.9151 GB, free: 48.47 MB / 0.6042 GB Notification: Performance of postOpt removeConstants (simulation): time 3.527e-05/0.255, allocations: 186 kB / 0.9153 GB, free: 48.26 MB / 0.6042 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 3.455e-05/0.2551, allocations: 184.3 kB / 0.9154 GB, free: 48.07 MB / 0.6042 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 5.461e-05/0.2551, allocations: 108.9 kB / 0.9155 GB, free: 47.96 MB / 0.6042 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 2.743e-05/0.2552, allocations: 176.3 kB / 0.9157 GB, free: 47.78 MB / 0.6042 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 1.888e-05/0.2552, allocations: 104.9 kB / 0.9158 GB, free: 47.67 MB / 0.6042 GB Notification: Performance of sorting global known variables: time 4.064e-05/0.2552, allocations: 103.2 kB / 0.9159 GB, free: 47.57 MB / 0.6042 GB Notification: Performance of sort global known variables: time 1.8e-07/0.2552, allocations: 0 / 0.9159 GB, free: 47.57 MB / 0.6042 GB Notification: Performance of remove unused functions: time 0.0007416/0.256, allocations: 283.8 kB / 0.9162 GB, free: 47.29 MB / 0.6042 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 1 * Number of states: 0 () * Number of discrete variables: 0 () * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (0): * Single equations (assignments): 0 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 Notification: Performance of Backend phase and start with SimCode phase: time 0.001367/0.2574, allocations: 1.183 MB / 0.9173 GB, free: 46.09 MB / 0.6042 GB Notification: Performance of simCode: created initialization part: time 8.483e-05/0.2575, allocations: 41.64 kB / 0.9174 GB, free: 46.05 MB / 0.6042 GB Notification: Performance of simCode: created event and clocks part: time 2.334e-06/0.2575, allocations: 4.062 kB / 0.9174 GB, free: 46.04 MB / 0.6042 GB Notification: Performance of simCode: created simulation system equations: time 1.743e-06/0.2575, allocations: 0 / 0.9174 GB, free: 46.04 MB / 0.6042 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.0003219/0.2578, allocations: 0.5263 MB / 0.9179 GB, free: 45.51 MB / 0.6042 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.001142/0.259, allocations: 1.593 MB / 0.9194 GB, free: 43.84 MB / 0.6042 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.0001132/0.2591, allocations: 0.6809 MB / 0.9201 GB, free: 43.14 MB / 0.6042 GB Notification: Performance of simCode: alias equations: time 1.5e-05/0.2591, allocations: 3.906 kB / 0.9201 GB, free: 43.13 MB / 0.6042 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 2.264e-05/0.2591, allocations: 19.44 kB / 0.9201 GB, free: 43.11 MB / 0.6042 GB Notification: Performance of SimCode: time 2.91e-07/0.2591, allocations: 0 / 0.9201 GB, free: 43.11 MB / 0.6042 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 0.01837/0.2775, allocations: 6.836 MB / 0.9268 GB, free: 36.5 MB / 0.6042 GB Notification: Performance of buildModelFMU: configured platform static using cached values: time 0.0001675/0.2777, allocations: 359.8 kB / 0.9271 GB, free: 36.11 MB / 0.6042 GB Error: Error building simulator. Build log: clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative.c:7: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_functions.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_functions.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_functions.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_functions.h:3: In file included from ./meta/meta_modelica.h:49: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_records.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_records.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_records.c:4: In file included from ./meta/meta_modelica.h:49: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_01exo.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_01exo.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_01exo.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_02nls.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_02nls.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_02nls.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_03lsy.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_03lsy.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_03lsy.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_04set.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_04set.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_04set.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_05evt.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_05evt.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_05evt.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_06inz.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_06inz.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_06inz.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_07dly.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_07dly.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_07dly.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_08bnd.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_08bnd.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_08bnd.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_09alg.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_09alg.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_09alg.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_10asr.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_10asr.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_10asr.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_11mix.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_11mix.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_11mix.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_12jac.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_12jac.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_12jac.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_13opt.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_13opt.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_13opt.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_14lnz.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_14lnz.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_14lnz.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_15syn.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_15syn.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_15syn.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_16dae.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_16dae.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_16dae.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_17inl.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_17inl.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_17inl.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_18spd.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_18spd.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_18spd.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_init_fmu.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_init_fmu.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_init_fmu.c:1: In file included from ./simulation_data.h:39: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_FMU.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_FMU.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_FMU.c:9: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_FMU.c:59: ./fmi-export/fmu2_model_interface.c.inc:213:16: warning: passing 'char **' to parameter of type 'const char **' discards qualifiers in nested pointer types [-Wincompatible-pointer-types-discards-qualifiers] GC_vasprintf(&str, msg, args); ^~~~ ./gc/../meta/../util/modelica_string.h:71:31: note: passing argument to parameter 'strp' here int GC_vasprintf(const char **strp, const char *fmt, va_list ap); ^ 3 warnings generated. mkdir -p ../binaries/linux64 clang -shared -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative.so Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_functions.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_records.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_01exo.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_02nls.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_03lsy.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_04set.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_05evt.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_06inz.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_07dly.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_08bnd.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_09alg.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_10asr.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_11mix.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_12jac.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_13opt.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_14lnz.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_15syn.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_16dae.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_17inl.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_18spd.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_init_fmu.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTubeNegative_FMU.o -L"/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Geothermal/Borefields/BaseClasses/Boreholes/BaseClasses/Functions/Validation" "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc" "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/" "-L/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Resources/Library/x86_64-linux" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Resources/Library/x86_64-linux" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Resources/Library/linux64" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Resources/Library/linux64" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Resources/Library" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Resources/Library" -lModelicaExternalC -Wl,-Bdynamic -L'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc' -Wl,-rpath,'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc' -Wl,-Bstatic -lSimulationRuntimeFMI -Wl,--no-as-needed -Wl,--disable-new-dtags -llapack -lblas -Wl,-Bdynamic -lm -lpthread -rdynamic -Wl,--no-undefined /usr/bin/ld: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libModelicaExternalC.a(ModelicaInternal.c.o): in function `ModelicaInternal_temporaryFileName': ModelicaInternal.c:(.text+0xac7): warning: the use of `tmpnam' is dangerous, better use `mkstemp' /usr/bin/ld: /usr/bin/../lib/gcc/x86_64-linux-gnu/9/../../../x86_64-linux-gnu/liblapack.a(dtrtri.o): in function `dtrtri_': (.text+0x197): undefined reference to `_gfortran_concat_string' clang: error: linker command failed with exit code 1 (use -v to see invocation) make: *** [Makefile:65: nozip] Error 1