/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WaterHeater_T_res.mat --tempDir=temp_Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WaterHeater_T_fmu --startTime=0 --stopTime=172800 --timeout=50 --tolerance=1e-06 Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WaterHeater_T.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WaterHeater_T/temp_Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WaterHeater_T_fmu/model-b6gs9gfq/temp/0001_Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WaterHeater_T (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 not (mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Buildings.Fluid.HeatExchangers.Examples.WaterHeater_T.mov: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WaterHeater_T/temp_Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WaterHeater_T_fmu/model-b6gs9gfq/temp/0001_Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WaterHeater_T (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 mov.per.haveWMot_nominal or not (mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Buildings.Fluid.HeatExchangers.Examples.WaterHeater_T.mov: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WaterHeater_T_res.mat (bufferSize=1) error: [operator()] Timeout occurred during simulation info: 2 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WaterHeater_T/temp_Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WaterHeater_T_fmu/model-b6gs9gfq/temp/0001_Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WaterHeater_T (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [doStep] fmi2_setTime failed for FMU "model.root.Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WaterHeater_T"