/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling_res.mat --tempDir=temp_Buildings_latest_Buildings_Experimental_DHC_Loads_BaseClasses_Validation_TerminalUnitScaling_fmu --startTime=0 --stopTime=1000 --timeout=50 --tolerance=1e-06 Buildings_latest_Buildings_Experimental_DHC_Loads_BaseClasses_Validation_TerminalUnitScaling.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling/temp_Buildings_latest_Buildings_Experimental_DHC_Loads_BaseClasses_Validation_TerminalUnitScaling_fmu/model-wayc155b/temp/0001_Buildings_latest_Buildings_Experimental_DHC_Loads_BaseClasses_Validation_TerminalUnitScaling (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 false assert | warning | *** Warning in Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling.ter.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling/temp_Buildings_latest_Buildings_Experimental_DHC_Loads_BaseClasses_Validation_TerminalUnitScaling_fmu/model-wayc155b/temp/0001_Buildings_latest_Buildings_Experimental_DHC_Loads_BaseClasses_Validation_TerminalUnitScaling (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 false assert | warning | *** Warning in Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling.ter.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling/temp_Buildings_latest_Buildings_Experimental_DHC_Loads_BaseClasses_Validation_TerminalUnitScaling_fmu/model-wayc155b/temp/0001_Buildings_latest_Buildings_Experimental_DHC_Loads_BaseClasses_Validation_TerminalUnitScaling (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 false assert | warning | *** Warning in Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling.terUniMul.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling/temp_Buildings_latest_Buildings_Experimental_DHC_Loads_BaseClasses_Validation_TerminalUnitScaling_fmu/model-wayc155b/temp/0001_Buildings_latest_Buildings_Experimental_DHC_Loads_BaseClasses_Validation_TerminalUnitScaling (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 false assert | warning | *** Warning in Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling.terUniMul.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling/temp_Buildings_latest_Buildings_Experimental_DHC_Loads_BaseClasses_Validation_TerminalUnitScaling_fmu/model-wayc155b/temp/0001_Buildings_latest_Buildings_Experimental_DHC_Loads_BaseClasses_Validation_TerminalUnitScaling (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 false assert | warning | *** Warning in Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling.terUniMulZonMul.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling/temp_Buildings_latest_Buildings_Experimental_DHC_Loads_BaseClasses_Validation_TerminalUnitScaling_fmu/model-wayc155b/temp/0001_Buildings_latest_Buildings_Experimental_DHC_Loads_BaseClasses_Validation_TerminalUnitScaling (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 false assert | warning | *** Warning in Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling.terUniMulZonMul.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_latest_Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling_res.mat (bufferSize=1) error: [operator()] Timeout occurred during simulation info: 6 warnings info: 1 errors