/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl_res.mat --tempDir=temp_Buildings_latest_Buildings_Examples_ChillerPlant_BaseClasses_Controls_Examples_ChillerSetPointControl_fmu --startTime=0 --stopTime=86400 --timeout=50 --tolerance=1e-06 Buildings_latest_Buildings_Examples_ChillerPlant_BaseClasses_Controls_Examples_ChillerSetPointControl.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl/temp_Buildings_latest_Buildings_Examples_ChillerPlant_BaseClasses_Controls_Examples_ChillerSetPointControl_fmu/model-8gnwtnyq/temp/0001_Buildings_latest_Buildings_Examples_ChillerPlant_BaseClasses_Controls_Examples_ChillerSetPointControl (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389: The following assertion has been violated during initialization at time 0.000000 pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning in Buildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl.pum: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl/temp_Buildings_latest_Buildings_Examples_ChillerPlant_BaseClasses_Controls_Examples_ChillerSetPointControl_fmu/model-8gnwtnyq/temp/0001_Buildings_latest_Buildings_Examples_ChillerPlant_BaseClasses_Controls_Examples_ChillerSetPointControl (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 not (pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Buildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl.pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl/temp_Buildings_latest_Buildings_Examples_ChillerPlant_BaseClasses_Controls_Examples_ChillerSetPointControl_fmu/model-8gnwtnyq/temp/0001_Buildings_latest_Buildings_Examples_ChillerPlant_BaseClasses_Controls_Examples_ChillerSetPointControl (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 pum.per.haveWMot_nominal or not (pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Buildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl.pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_latest_Buildings.Examples.ChillerPlant.BaseClasses.Controls.Examples.ChillerSetPointControl_res.mat (bufferSize=1) error: [operator()] Timeout occurred during simulation info: 3 warnings info: 1 errors