/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanCVF.Subsequences.Validation.Alarms_res.mat --tempDir=temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms_fmu --startTime=0 --stopTime=7200 --timeout=50 --tolerance=1e-06 Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms.fmu info: model doesn't contain any continuous state warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanCVF.Subsequences.Validation.Alarms/temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms_fmu/model-rzhifztg/temp/0001_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated during initialization at time 0.000000 ala.not10.y assert | warning | Warning: fan has been commanded ON but still OFF. info: Result file: Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanCVF.Subsequences.Validation.Alarms_res.mat (bufferSize=1) info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms.ala.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms.ala.assMes1.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms.ala.assMes2.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms.ala.assMes3.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms.ala.assMes4.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms.ala.assMes5.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms.ala.assMes6.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms.ala.assMes7.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms.ala.assMes8.message will not be stored in the result file, because the signal type is not supported warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanCVF.Subsequences.Validation.Alarms/temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms_fmu/model-rzhifztg/temp/0001_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated at time 850.000000 ala.not7.y assert | warning | Warning: discharge air temperature is 8 degC less than the setpoint. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanCVF.Subsequences.Validation.Alarms/temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms_fmu/model-rzhifztg/temp/0001_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanCVF_Subsequences_Validation_Alarms (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated at time 954.546000 ala.not2.y assert | warning | Warning: airflow is less than 7021604567006f the setpoint. error: [operator()] Timeout occurred during simulation info: 3 warnings info: 1 errors