/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36_res.mat --tempDir=temp_Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36_fmu --startTime=0 --stopTime=864000 --timeout=50 --tolerance=1e-06 Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36.fmu stdout | info | Using sparse solver for linear system 10, | | | | because density of 0.160 remains under threshold of 0.200. stdout | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. stdout | info | Using sparse solver for linear system 22, | | | | because density of 0.160 remains under threshold of 0.200. stdout | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. stdout | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36/temp_Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36_fmu/model-9f0m5i96/temp/0001_Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36 (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 false assert | warning | *** Warning in Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36.hvac.pumChiWat: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36/temp_Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36_fmu/model-9f0m5i96/temp/0001_Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36 (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 false assert | warning | *** Warning in Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36.hvac.pumChiWat: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36/temp_Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36_fmu/model-9f0m5i96/temp/0001_Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36 (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Controls/OBC/ASHRAE/G36/AHUs/SingleZone/VAV/Controller.mo:766: The following assertion has been violated at time 0.000000 con.ySupFan >= max(0.0, max(0.0, max(con.conEco.supFanSpe_min, 0.0))) and con.ySupFan <= min(1.0, min(1.0, min(con.conEco.supFanSpe_max, 1.0))) assert | warning | Variable violating min/max constraint: max(0.0, max(0.0, max(con.conEco.supFanSpe_min, 0.0))) <= con.ySupFan <= min(1.0, min(1.0, min(con.conEco.supFanSpe_max, 1.0))), has value: 0 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36/temp_Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36_fmu/model-9f0m5i96/temp/0001_Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36 (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Controls/OBC/ASHRAE/G36/VentilationZones/ASHRAE62_1/Setpoints.mo:130: The following assertion has been violated at time 0.000000 con.outAirSetPoi.VMinOA_flow >= 0.0144 and con.outAirSetPoi.VMinOA_flow <= min(con.conEco.damLim.VOutDes_flow, con.conEco.VOutDes_flow) assert | warning | Variable violating min/max constraint: 0.0144 <= con.outAirSetPoi.VMinOA_flow <= min(con.conEco.damLim.VOutDes_flow, con.conEco.VOutDes_flow), has value: 0 assert | debug | division by zero at time 0, (a=0) / (b=0), where divisor b expression is: hvac.cooCoi.m1_flow + hvac.ideVal.preMasFlo.m_flow error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36/temp_Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36_fmu/model-9f0m5i96/temp/0001_Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36 (logFmi2Call): internalEventUpdate: terminated by an assertion. error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.Buildings_latest_Buildings_Air_Systems_SingleZone_VAV_Examples_Guideline36" error: [initialize] Initialization of system "model.root" failed error: [simulate] Model "model" is in wrong model state info: 4 warnings info: 4 errors