OMSimulator --tempDir=temp_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise_fmu --startTime=1.728e+07 --stopTime=1.78848e+07 --timeout=50 --tolerance=1e-06 Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise.fmu info: model doesn't contain any continuous state warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.Sources.Examples.Outside_CpLowRise/temp_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise_fmu/model-xdf8hyu2/temp/0001_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Sources/Outside_CpLowRise.mo:14: The following assertion has been violated at time 0.000000 west.CpAct >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= west.CpAct, has value: -0.46487 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.Sources.Examples.Outside_CpLowRise/temp_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise_fmu/model-xdf8hyu2/temp/0001_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Utilities/Psychrometrics/TWetBul_TDryBulPhi.mo:40: The following assertion has been violated at time 0.000000 weaDat.tWetBul_TDryBulXi.XiSat >= 0.0 and weaDat.tWetBul_TDryBulXi.XiSat <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.tWetBul_TDryBulXi.XiSat <= 1.0, has value: -1.64772 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.Sources.Examples.Outside_CpLowRise/temp_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise_fmu/model-xdf8hyu2/temp/0001_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Utilities/Psychrometrics/TWetBul_TDryBulPhi.mo:41: The following assertion has been violated at time 0.000000 weaDat.tWetBul_TDryBulXi.XiSatRefIn >= 0.0 and weaDat.tWetBul_TDryBulXi.XiSatRefIn <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.tWetBul_TDryBulXi.XiSatRefIn <= 1.0, has value: -0.61881 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.Sources.Examples.Outside_CpLowRise/temp_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise_fmu/model-xdf8hyu2/temp/0001_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Sources/Outside_CpLowRise.mo:14: The following assertion has been violated at time 0.000000 south.CpAct >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= south.CpAct, has value: -0.162766 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.Sources.Examples.Outside_CpLowRise/temp_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise_fmu/model-xdf8hyu2/temp/0001_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Sources/Outside_CpLowRise.mo:14: The following assertion has been violated at time 0.000000 east.CpAct >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= east.CpAct, has value: -0.46487 info: Result file: model_res.mat (bufferSize=10) error: [operator()] Timeout occurred during simulation info: 5 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.Sources.Examples.Outside_CpLowRise/temp_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise_fmu/model-xdf8hyu2/temp/0001_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [updateInputs] fmi2_setTime failed for FMU "model.root.Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.Sources.Examples.Outside_CpLowRise/temp_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise_fmu/model-xdf8hyu2/temp/0001_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_error state. error: [doStep] fmi2_setTime failed for FMU "model.root.Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.Sources.Examples.Outside_CpLowRise/temp_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise_fmu/model-xdf8hyu2/temp/0001_Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise (logStatusError): fmi2CompletedIntegratorStep: Illegal model exchange call sequence. fmi2CompletedIntegratorStep is not allowed in model_state_error state. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.Buildings_8_Buildings_Fluid_Sources_Examples_Outside_CpLowRise"