OMSimulator --tempDir=temp_Buildings_8_Buildings_Fluid_SolarCollectors_Examples_Tubular_fmu --startTime=0 --stopTime=86400 --timeout=50 --tolerance=1e-06 Buildings_8_Buildings_Fluid_SolarCollectors_Examples_Tubular.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.SolarCollectors.Examples.Tubular/temp_Buildings_8_Buildings_Fluid_SolarCollectors_Examples_Tubular_fmu/model-7cxryt87/temp/0001_Buildings_8_Buildings_Fluid_SolarCollectors_Examples_Tubular (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Utilities/Psychrometrics/TWetBul_TDryBulPhi.mo:40: The following assertion has been violated at time 0.000000 weaDat.tWetBul_TDryBulXi.XiSat >= 0.0 and weaDat.tWetBul_TDryBulXi.XiSat <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.tWetBul_TDryBulXi.XiSat <= 1.0, has value: -1.64772 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.SolarCollectors.Examples.Tubular/temp_Buildings_8_Buildings_Fluid_SolarCollectors_Examples_Tubular_fmu/model-7cxryt87/temp/0001_Buildings_8_Buildings_Fluid_SolarCollectors_Examples_Tubular (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Utilities/Psychrometrics/TWetBul_TDryBulPhi.mo:41: The following assertion has been violated at time 0.000000 weaDat.tWetBul_TDryBulXi.XiSatRefIn >= 0.0 and weaDat.tWetBul_TDryBulXi.XiSatRefIn <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.tWetBul_TDryBulXi.XiSatRefIn <= 1.0, has value: -0.61881 info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) error: [operator()] Timeout occurred during simulation info: 2 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.SolarCollectors.Examples.Tubular/temp_Buildings_8_Buildings_Fluid_SolarCollectors_Examples_Tubular_fmu/model-7cxryt87/temp/0001_Buildings_8_Buildings_Fluid_SolarCollectors_Examples_Tubular (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [updateInputs] fmi2_setTime failed for FMU "model.root.Buildings_8_Buildings_Fluid_SolarCollectors_Examples_Tubular" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.SolarCollectors.Examples.Tubular/temp_Buildings_8_Buildings_Fluid_SolarCollectors_Examples_Tubular_fmu/model-7cxryt87/temp/0001_Buildings_8_Buildings_Fluid_SolarCollectors_Examples_Tubular (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_8_Buildings_Fluid_SolarCollectors_Examples_Tubular" info: Final Statistics for 'model.root': NumSteps = 347010 NumRhsEvals = 347011 NumLinSolvSetups = 17352 NumNonlinSolvIters = 347010 NumNonlinSolvConvFails = 0 NumErrTestFails = 0