OMSimulator --tempDir=temp_Buildings_8_Buildings_Examples_Tutorial_Boiler_System6_fmu --startTime=0 --stopTime=172800 --timeout=50 --tolerance=1e-06 Buildings_8_Buildings_Examples_Tutorial_Boiler_System6.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Examples.Tutorial.Boiler.System6/temp_Buildings_8_Buildings_Examples_Tutorial_Boiler_System6_fmu/model-s6vvkexl/temp/0001_Buildings_8_Buildings_Examples_Tutorial_Boiler_System6 (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352: The following assertion has been violated during initialization at time 0.000000 pumRad.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Examples.Tutorial.Boiler.System6/temp_Buildings_8_Buildings_Examples_Tutorial_Boiler_System6_fmu/model-s6vvkexl/temp/0001_Buildings_8_Buildings_Examples_Tutorial_Boiler_System6 (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352: The following assertion has been violated during initialization at time 0.000000 pumBoi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) error: [operator()] Timeout occurred during simulation info: 2 warnings info: 1 errors info: Final Statistics for 'model.root': NumSteps = 149001 NumRhsEvals = 149004 NumLinSolvSetups = 7452 NumNonlinSolvIters = 149003 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 [CVODE ERROR] CVode cvode_mem = NULL illegal. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -21