/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly_res.mat --tempDir=temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu --startTime=0 --stopTime=360000 --timeout=50 --tolerance=1e-06 Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly/temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu/model-5jkofw5a/temp/0001_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 not (ets.hex.pum1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.hex.pum1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly.ets.hex.pum1: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly/temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu/model-5jkofw5a/temp/0001_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 ets.hex.pum1.per.haveWMot_nominal or not (ets.hex.pum1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.hex.pum1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly.ets.hex.pum1: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly/temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu/model-5jkofw5a/temp/0001_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 not (ets.hex.pum2.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.hex.pum2.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly.ets.hex.pum2: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly/temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu/model-5jkofw5a/temp/0001_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 ets.hex.pum2.per.haveWMot_nominal or not (ets.hex.pum2.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.hex.pum2.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly.ets.hex.pum2: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly/temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu/model-5jkofw5a/temp/0001_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 not (ets.chi.pumCon.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.chi.pumCon.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly.ets.chi.pumCon: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly/temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu/model-5jkofw5a/temp/0001_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 ets.chi.pumCon.per.haveWMot_nominal or not (ets.chi.pumCon.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.chi.pumCon.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly.ets.chi.pumCon: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly/temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu/model-5jkofw5a/temp/0001_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 not (ets.chi.pumEva.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.chi.pumEva.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly.ets.chi.pumEva: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly/temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu/model-5jkofw5a/temp/0001_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 ets.chi.pumEva.per.haveWMot_nominal or not (ets.chi.pumEva.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.chi.pumEva.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly.ets.chi.pumEva: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly/temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu/model-5jkofw5a/temp/0001_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 not (pumChiWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumChiWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly.pumChiWat: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly/temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu/model-5jkofw5a/temp/0001_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 pumChiWat.per.haveWMot_nominal or not (pumChiWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumChiWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly.pumChiWat: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly/temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu/model-5jkofw5a/temp/0001_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 not (pumHeaWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumHeaWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly.pumHeaWat: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly/temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu/model-5jkofw5a/temp/0001_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 pumHeaWat.per.haveWMot_nominal or not (pumHeaWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumHeaWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly.pumHeaWat: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | debug | division by zero at time 0, (a=0) / (b=0), where divisor b expression is: 0.0 error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly/temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu/model-5jkofw5a/temp/0001_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly (logFmi2Call): internalEventUpdate: terminated by an assertion. assert | debug | division by zero at time 0, (a=0) / (b=0), where divisor b expression is: 0.0 error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerOnly/temp_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly_fmu/model-5jkofw5a/temp/0001_Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly (logFmi2Call): internalEventUpdate: terminated by an assertion. error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.Buildings_10_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Validation_ChillerOnly" error: [initialize] Initialization of system "model.root" failed error: [simulate] Model "model" is in wrong model state info: 12 warnings info: 5 errors