OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Fluid_HeatExchangers_Examples_WaterHeater_u_fmu --startTime=0 --stopTime=172800 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Fluid_HeatExchangers_Examples_WaterHeater_u.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.HeatExchangers.Examples.WaterHeater_u/temp_BuildingSystems_BuildingSystems_Fluid_HeatExchangers_Examples_WaterHeater_u_fmu/model-30twq86l/temp/0001_BuildingSystems_BuildingSystems_Fluid_HeatExchangers_Examples_WaterHeater_u (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417: The following assertion has been violated during initialization at time 0.000000 not (mov.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or mov.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in BuildingSystems.Fluid.HeatExchangers.Examples.WaterHeater_u.mov: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.HeatExchangers.Examples.WaterHeater_u/temp_BuildingSystems_BuildingSystems_Fluid_HeatExchangers_Examples_WaterHeater_u_fmu/model-30twq86l/temp/0001_BuildingSystems_BuildingSystems_Fluid_HeatExchangers_Examples_WaterHeater_u (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:428: The following assertion has been violated during initialization at time 0.000000 mov.per.haveWMot_nominal or not (mov.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or mov.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in BuildingSystems.Fluid.HeatExchangers.Examples.WaterHeater_u.mov: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) error: [operator()] Timeout occurred during simulation info: 2 warnings info: 1 errors