OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated_fmu --startTime=0 --stopTime=3600 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Zones.Examples.SingleZoneVentilated/temp_BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated_fmu/model-xx7knhep/temp/0001_BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Airflow/Multizone/MediumColumn.mo:10: The following assertion has been violated at time 0.000000 zone.airpath[2].h >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= zone.airpath[2].h, has value: -1.4 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Zones.Examples.SingleZoneVentilated/temp_BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated_fmu/model-xx7knhep/temp/0001_BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Airflow/Multizone/MediumColumn.mo:10: The following assertion has been violated at time 0.000000 zone.airpath[1].h >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= zone.airpath[1].h, has value: -1.4 info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.wall.construction.layer[1].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.wall.construction.layer[2].material.name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.wall.construction.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.wall.construction.material[2].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.wall.constructionData.material[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.wall.constructionData.material[2].name will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 2 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Zones.Examples.SingleZoneVentilated/temp_BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated_fmu/model-xx7knhep/temp/0001_BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [doStep] fmi2_setTime failed for FMU "model.root.BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated"