/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_FMI_Validation_HeaterFan_fmu --startTime=0 --stopTime=1 --timeout=50 --tolerance=1e-06 BuildSysPro_BuildSysPro_IBPSA_Fluid_FMI_Validation_HeaterFan.fmu info: model doesn't contain any continuous state warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.FMI.Validation.HeaterFan/temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_FMI_Validation_HeaterFan_fmu/model-n55ce9cm/temp/0001_BuildSysPro_BuildSysPro_IBPSA_Fluid_FMI_Validation_HeaterFan (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387: The following assertion has been violated during initialization at time 0.000000 false assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.FMI.Validation.HeaterFan/temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_FMI_Validation_HeaterFan_fmu/model-n55ce9cm/temp/0001_BuildSysPro_BuildSysPro_IBPSA_Fluid_FMI_Validation_HeaterFan (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420: The following assertion has been violated during initialization at time 0.000000 false assert | warning | *** Warning in BuildSysPro.IBPSA.Fluid.FMI.Validation.HeaterFan.floMac.com: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.FMI.Validation.HeaterFan/temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_FMI_Validation_HeaterFan_fmu/model-n55ce9cm/temp/0001_BuildSysPro_BuildSysPro_IBPSA_Fluid_FMI_Validation_HeaterFan (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 false assert | warning | *** Warning in BuildSysPro.IBPSA.Fluid.FMI.Validation.HeaterFan.floMac.com: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead. info: Result file: model_res.mat (bufferSize=10) info: 3 warnings info: 0 errors