Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IndustrialControlSystems_IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo", uses=false) Using package IndustrialControlSystems with version 1.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IndustrialControlSystems_IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning") translateModel(IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IndustrialControlSystems_IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009344/0.0009349, allocations: 92.23 kB / 16.02 MB, free: 80 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.00124/0.00124, allocations: 177.3 kB / 16.92 MB, free: 6.648 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.011/2.011, allocations: 205.4 MB / 223.1 MB, free: 5.555 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo): time 0.05609/0.05609, allocations: 10.75 MB / 282.1 MB, free: 10.46 MB / 238.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.0008117/0.0008116, allocations: 16.22 kB / 342.9 MB, free: 23.51 MB / 254.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1173/0.1181, allocations: 50.01 MB / 392.9 MB, free: 5.438 MB / 286.1 MB Notification: Performance of NFInst.instantiate(IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning): time 0.008963/0.1271, allocations: 7.389 MB / 400.3 MB, free: 14 MB / 302.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/Controllers/AutoTuning/ATPIrelayNCmixedMode.mo:91:8-91:29:writable] Error: Operator reinit may only be used in the body of a when equation. Notification: Performance of FrontEnd: time 0.004343/0.1315, allocations: 1.742 MB / 402 MB, free: 12.26 MB / 302.1 MB