Environment - simulationEnvironment: startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS WARNING: other : Warning: unrecognized command line options -abortSlowSimulation INFO : solver: SimManager: Start initialization ... loading "EnergyPlus" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Resources/Data/ThermalZones/EnergyPlus_9_6_0/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.04.08 19:07 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD Output Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.inf1.y has in Modelica the unit 1. INFO : solver: SimManager: Start simulation at t = 0.000000 INFO : solver: SimManager: Simulation stop time: 604800.000000 INFO : solver: Simulation info from solver: INFO : solver: DASSL: steps taken nst = 10592 INFO : solver: DASSL: residual evaluations nre = 20298 INFO : solver: DASSL: jacobian evaluations nje = 6178 INFO : solver: DASSL: root evaluations nrt = 12607 INFO : solver: DASSL: error test failures netf = 1996 INFO : solver: DASSL: nonlinear convergence failures ncfn = 0 INFO : solver: DASSL: nonlinear iterations nni = 20298 INFO : solver: DASSL: last evaluation time t = 604905.966840 INFO : solver: DASSL: last step size h = 120.960000 INFO : solver: DASSL: last used order k = 2 Writing tabular output file results using HTML format. Writing final SQL reports EnergyPlus Run Time=00hr 00min 0.55sec EnergyPlus Completed Successfully. 604800.000 Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.building: Warning from EnergyPlus: The following schedule names are "Unused Schedules". These schedules are in the idf 604800.000 Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. 604800.000 Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.building: Warning from EnergyPlus: The following week schedule names are "Unused Schedules". These schedules are in the idf 604800.000 Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. 604800.000 Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.building: Warning from EnergyPlus: The following day schedule names are "Unused Schedules". These schedules are in the idf 604800.000 Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used.