Environment - simulationEnvironment: startTime=0 stopTime=8000 tolerance=1e-06 numberOfIntervals=2500 stepSize=3.2 Regular simulation: ./ThermoPower_ThermoPower.Test.WaterComponents.TestAccumulator -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | warning | The following assertion has been violated at time 500.800000 | | | | Accumulator1.zl >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= Accumulator1.zl, has value: -3.85367e-06 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00205941s reading init.xml | | | | | | 0.000155091s reading info.xml | | | | | | 9.2824e-05s [ 0.1%] pre-initialization | | | | | | 0.00102963s [ 1.0%] initialization | | | | | | 1.3225e-05s [ 0.0%] steps | | | | | | 0.00148421s [ 1.5%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0414009s [ 41.7%] event-handling | | | | | | 0.00657419s [ 6.6%] overhead | | | | | | 0.0485873s [ 49.0%] simulation | | | | | | 0.0991824s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 257 steps taken | | | | | | 314 calls of functionODE | | | | | | 87 evaluations of jacobian | | | | | | 1 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0025349s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.