Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr ThermoPower_ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo", uses=false) Using package ThermoPower with version 3.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100000,variableFilter="",fileNamePrefix="ThermoPower_ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE") translateModel(ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100000,variableFilter="",fileNamePrefix="ThermoPower_ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009469/0.0009468, allocations: 95.52 kB / 16.31 MB, free: 5.945 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009907/0.000991, allocations: 179.5 kB / 17.2 MB, free: 5.859 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.465/1.465, allocations: 205.4 MB / 223.4 MB, free: 5.219 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo): time 0.5224/0.5224, allocations: 48.77 MB / 320.4 MB, free: 3.871 MB / 254.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.0005728/0.0005731, allocations: 12.62 kB / 391.2 MB, free: 14.3 MB / 334.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1624/0.163, allocations: 60.26 MB / 451.4 MB, free: 1.891 MB / 382.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/PowerPlants.mo:18204:30-18204:37:writable] Error: Modified element Pn not found in class Grid. Notification: Performance of FrontEnd: time 0.001614/0.1647, allocations: 1.006 MB / 452.4 MB, free: 0.875 MB / 382.1 MB