Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr SiemensPower_SiemensPower.Components.Pipes.Tests.tube_ownMedia_test.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo", uses=false) Using package SiemensPower with version 2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(SiemensPower.Components.Pipes.Tests.tube_ownMedia_test,tolerance=1e-05,outputFormat="empty",numberOfIntervals=4000,variableFilter="",fileNamePrefix="SiemensPower_SiemensPower.Components.Pipes.Tests.tube_ownMedia_test") translateModel(SiemensPower.Components.Pipes.Tests.tube_ownMedia_test,tolerance=1e-05,outputFormat="empty",numberOfIntervals=4000,variableFilter="",fileNamePrefix="SiemensPower_SiemensPower.Components.Pipes.Tests.tube_ownMedia_test") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001105/0.001105, allocations: 84.38 kB / 15.06 MB, free: 1.09 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001058/0.001058, allocations: 168.7 kB / 15.95 MB, free: 204 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.793/1.793, allocations: 205.4 MB / 222.1 MB, free: 5.641 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo): time 0.03152/0.03152, allocations: 5.552 MB / 275.9 MB, free: 15.77 MB / 238.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: SiemensPower requested package Modelica of version 3.2.1. Modelica 3.2.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.0005851/0.0005851, allocations: 19.11 kB / 335.3 MB, free: 29.41 MB / 254.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1142/0.1148, allocations: 48.86 MB / 384.2 MB, free: 12.53 MB / 286.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/Interfaces/portHeat.mo:15:3-15:40:writable] Error: Modifier '= TWall' found on outer element TWall. Notification: Performance of FrontEnd: time 0.0247/0.1395, allocations: 21.66 MB / 405.8 MB, free: 6.801 MB / 302.1 MB