Environment - simulationEnvironment: startTime=0 stopTime=150 tolerance=1e-05 numberOfIntervals=2500 stepSize=0.06 Regular simulation: ./SiemensPower_SiemensPower.Components.Pipes.Tests.TubeWithoutWall -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0185338s reading init.xml | | | | | | 0.00145469s reading info.xml | | | | | | 0.000214021s [ 0.0%] pre-initialization | | | | | | 0.0350817s [ 0.6%] initialization | | | | | | 0.000486663s [ 0.0%] steps | | | | | | 0.0209529s [ 0.3%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 2.02136s [ 32.3%] event-handling | | | | | | 0.0214843s [ 0.3%] overhead | | | | | | 4.15047s [ 66.4%] simulation | | | | | | 6.25004s [100.0%] total | | | | | events | | | | | | 46 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 5868 steps taken | | | | | | 6677 calls of functionODE | | | | | | 500 evaluations of jacobian | | | | | | 9 error test failures | | | | | | 0 convergence test failures | | | | | | 1.16561s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.