Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr SiemensPower_SiemensPower.Components.HeatExchanger.Tests.ParallelFlowEvaporatorOwnMedia_test.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo", uses=false) Using package SiemensPower with version 2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(SiemensPower.Components.HeatExchanger.Tests.ParallelFlowEvaporatorOwnMedia_test,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="SiemensPower_SiemensPower.Components.HeatExchanger.Tests.ParallelFlowEvaporatorOwnMedia_test") translateModel(SiemensPower.Components.HeatExchanger.Tests.ParallelFlowEvaporatorOwnMedia_test,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="SiemensPower_SiemensPower.Components.HeatExchanger.Tests.ParallelFlowEvaporatorOwnMedia_test") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001013/0.001013, allocations: 86.56 kB / 15.06 MB, free: 1.09 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009288/0.0009288, allocations: 168.7 kB / 15.95 MB, free: 204 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.825/1.825, allocations: 205.4 MB / 222.1 MB, free: 5.379 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo): time 0.03102/0.03102, allocations: 5.562 MB / 276 MB, free: 15.62 MB / 238.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: SiemensPower requested package Modelica of version 3.2.1. Modelica 3.2.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.0005505/0.0005506, allocations: 12 kB / 335.3 MB, free: 29.39 MB / 254.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1012/0.1018, allocations: 48.87 MB / 384.2 MB, free: 12.51 MB / 286.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/Components/HeatExchanger/Tests/ParallelFlowEvaporatorOwnMedia_test.mo:79:7-79:20:writable] Error: Modified element use_h_in not found in class WaterSourceMH. Notification: Performance of FrontEnd: time 0.003399/0.1052, allocations: 2.603 MB / 386.8 MB, free: 9.891 MB / 286.1 MB