Environment - simulationEnvironment: startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2 -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Resources/weatherdata/USA_IL_Chicago-OHare.Intl.AP.725300_TMY3.mos" stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2.building: Using pre-compiled FMU /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Resources/src/ThermalZones/EnergyPlus_9_6_0/FMUs/Zones3.fmu stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2.building: Warning: Variable South_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2/spawn-Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2/EnergyPlus.fmu. It will not be converted to SI units. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2/spawn-Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2/EnergyPlus.fmu. It will not be converted to SI units. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.core.&##10;" stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.north.&##10;" stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.south.&##10;" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0040913s reading init.xml | | | | | | 0.000432181s reading info.xml | | | | | | 5.9561e-05s [ 0.1%] pre-initialization | | | | | | 0.0466265s [ 74.9%] initialization | | | | | | 1.613e-06s [ 0.0%] steps | | | | | | 0.00119372s [ 1.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0027135s [ 4.4%] event-handling | | | | | | 0.00364259s [ 5.9%] overhead | | | | | | 0.00802796s [ 12.9%] simulation | | | | | | 0.0622655s [100.0%] total | | | | | events | | | | | | 59 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1040 steps taken | | | | | | 1040 calls of functionODE | | | | | | 980 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000201044s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.