Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case620.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case620,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case620") translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case620,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case620") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.527/2.527, allocations: 287.5 MB / 302.4 MB, free: 8.238 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001293/0.001293, allocations: 180.6 kB / 371 MB, free: 10.87 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.14/2.14, allocations: 205.4 MB / 0.6297 GB, free: 10.63 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009748/0.0009744, allocations: 103 kB / 0.743 GB, free: 6.617 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004882/0.0004884, allocations: 12.5 kB / 0.8658 GB, free: 140.5 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2244/0.2249, allocations: 115.3 MB / 0.9784 GB, free: 28.36 MB / 0.6198 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case620): time 0.9937/1.219, allocations: 207.4 MB / 1.181 GB, free: 2.738 MB / 0.7136 GB Notification: Performance of NFInst.instExpressions: time 0.08875/1.307, allocations: 35.62 MB / 1.216 GB, free: 5.723 MB / 0.7448 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01674/1.324, allocations: 252.2 kB / 1.216 GB, free: 5.625 MB / 0.7448 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case620.mo:9:7-9:36:writable] Error: Component glaSys of variability parameter has binding '{window600, window600}[]' of higher variability continuous. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/HeatTransfer/Data/GlazingSystems.mo:9:5-11:33:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Math/BooleanVectors.mo:59:6-59:30:writable] Warning: Parameter roo.datConExtWin[2].glaSys.haveExteriorShade(fixed = true) has annotation(Evaluate=true) and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case620.mo:9:7-9:36:writable] Error: Component glaSys of variability parameter has binding '{window600, window600}[]' of higher variability continuous. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/HeatTransfer/Data/GlazingSystems.mo:9:5-11:33:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Math/BooleanVectors.mo:59:6-59:30:writable] Warning: Parameter roo.datConExtWin[2].glaSys.haveExteriorShade(fixed = true) has annotation(Evaluate=true) and no binding. [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFCeval.mo:1481:9-1481:67:writable] Error: Internal error NFCeval.evalLogicBinaryOr failed to evaluate ‘roo.datConExtWin[2].glaSys.haveExteriorShade or {roo.datConExtWin[2].glaSys.haveExteriorShade, roo.datConExtWin[2].glaSys.haveExteriorShade}[2]‘ Notification: Performance of FrontEnd: time 0.0274/1.352, allocations: 5.778 MB / 1.222 GB, free: 1.984 MB / 0.7448 GB