Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo", uses=false) Using package Buildings with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo) Running command: translateModel(Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM") translateModel(Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM") [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:257:38-257:110:writable] Warning: The file was not encoded in UTF-8: "

An important practical aspect of state machines is the abilit...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:761:36-761:108:writable] Warning: The file was not encoded in UTF-8: "

The Modelica_StateGraph2 library is described in detail in (O...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:1435:36-1435:108:writable] Warning: The file was not encoded in UTF-8: "

Main Authors:
SCode: time 0.1989/0.1997, allocations: 82.22 MB / 0.5935 GB, free: 5.977 MB / 446.1 MB Notification: Performance of NFInst.instantiate(Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM): time 0.005021/0.2048, allocations: 3.836 MB / 0.5972 GB, free: 2.113 MB / 446.1 MB Notification: Performance of NFInst.instExpressions: time 0.005533/0.2104, allocations: 2.596 MB / 0.5997 GB, free: 15.5 MB / 462.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0008577/0.2113, allocations: 15.94 kB / 0.5998 GB, free: 15.49 MB / 462.1 MB Notification: Performance of NFTyping.typeComponents: time 0.001228/0.2125, allocations: 286.4 kB / 0.6 GB, free: 15.21 MB / 462.1 MB Notification: Performance of NFTyping.typeBindings: time 0.001692/0.2142, allocations: 401.1 kB / 0.6004 GB, free: 14.82 MB / 462.1 MB Notification: Performance of NFTyping.typeClassSections: time 0.001289/0.2155, allocations: 386.8 kB / 0.6008 GB, free: 14.44 MB / 462.1 MB Notification: Performance of NFFlatten.flatten: time 0.002259/0.2178, allocations: 1.476 MB / 0.6022 GB, free: 12.96 MB / 462.1 MB Notification: Performance of NFFlatten.resolveConnections: time 0.0004576/0.2183, allocations: 165.5 kB / 0.6024 GB, free: 12.79 MB / 462.1 MB Notification: Performance of NFEvalConstants.evaluate: time 0.00117/0.2194, allocations: 0.5021 MB / 0.6029 GB, free: 12.28 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/HeatTransfer/Conduction/BaseClasses/temperature_u.mo:9:41-9:55:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/HeatTransfer/Conduction/BaseClasses/temperature_u.mo:9:3-10:46:writable] Error: Non-array modification ‘"kg.K2/J"‘ for array component ‘unit‘, possibly due to missing ‘each‘. Notification: Performance of FrontEnd: time 0.001004/0.2205, allocations: 0.5798 MB / 0.6034 GB, free: 11.7 MB / 462.1 MB