Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorMultiLayer.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo", uses=false) Using package Buildings with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo) Running command: translateModel(Buildings.HeatTransfer.Examples.ConductorMultiLayer,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorMultiLayer") translateModel(Buildings.HeatTransfer.Examples.ConductorMultiLayer,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorMultiLayer") [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:257:38-257:110:writable] Warning: The file was not encoded in UTF-8: "

An important practical aspect of state machines is the abilit...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:761:36-761:108:writable] Warning: The file was not encoded in UTF-8: "

The Modelica_StateGraph2 library is described in detail in (O...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:1435:36-1435:108:writable] Warning: The file was not encoded in UTF-8: "

Main Authors:
SCode: time 0.479/0.4799, allocations: 82.21 MB / 0.5935 GB, free: 21.41 MB / 446.1 MB Notification: Performance of NFInst.instantiate(Buildings.HeatTransfer.Examples.ConductorMultiLayer): time 0.002777/0.4827, allocations: 2.3 MB / 0.5957 GB, free: 19.09 MB / 446.1 MB Notification: Performance of NFInst.instExpressions: time 0.002952/0.4857, allocations: 2.5 MB / 0.5981 GB, free: 16.59 MB / 446.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0002198/0.486, allocations: 0 / 0.5981 GB, free: 16.59 MB / 446.1 MB Notification: Performance of NFTyping.typeComponents: time 0.00123/0.4872, allocations: 421 kB / 0.5985 GB, free: 16.18 MB / 446.1 MB Notification: Performance of NFTyping.typeBindings: time 0.000325/0.4875, allocations: 153.4 kB / 0.5987 GB, free: 16.03 MB / 446.1 MB Notification: Performance of NFTyping.typeClassSections: time 0.000413/0.488, allocations: 138.4 kB / 0.5988 GB, free: 15.9 MB / 446.1 MB Notification: Performance of NFFlatten.flatten: time 0.0008635/0.4888, allocations: 1.096 MB / 0.5999 GB, free: 14.8 MB / 446.1 MB Notification: Performance of NFFlatten.resolveConnections: time 0.0001787/0.489, allocations: 112.1 kB / 0.6 GB, free: 14.7 MB / 446.1 MB Notification: Performance of NFEvalConstants.evaluate: time 0.0004353/0.4895, allocations: 416.7 kB / 0.6004 GB, free: 14.29 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/HeatTransfer/Conduction/BaseClasses/temperature_u.mo:9:41-9:55:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/HeatTransfer/Conduction/BaseClasses/temperature_u.mo:9:3-10:46:writable] Error: Non-array modification ‘"kg.K2/J"‘ for array component ‘unit‘, possibly due to missing ‘each‘. Notification: Performance of FrontEnd: time 0.0003851/0.4899, allocations: 326.8 kB / 0.6007 GB, free: 13.97 MB / 446.1 MB