Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_3.0.0_Buildings.Fluid.SolarCollectors.Examples.FlatPlateWithTank -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/Resources/weatherdata/USA_CA_San.Francisco.Intl.AP.724940_TMY3.mos" assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | warning | The following assertion has been violated at time 14411.520000 | | | | weaDat.totSkyCov_in_internal >= 0.0 and weaDat.totSkyCov_in_internal <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.totSkyCov_in_internal <= 1.0, has value: -0.000181577 assert | warning | The following assertion has been violated at time 14411.520000 | | | | weaDat.opaSkyCov_in_internal >= 0.0 and weaDat.opaSkyCov_in_internal <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.opaSkyCov_in_internal <= 1.0, has value: -0.000181577 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0434257s reading init.xml | | | | | | 0.00319063s reading info.xml | | | | | | 0.000232206s [ 0.1%] pre-initialization | | | | | | 0.0162815s [ 6.8%] initialization | | | | | | 2.6179e-05s [ 0.0%] steps | | | | | | 0.00540288s [ 2.3%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000832477s [ 0.3%] event-handling | | | | | | 0.0173525s [ 7.3%] overhead | | | | | | 0.198665s [ 83.2%] simulation | | | | | | 0.238793s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1147 steps taken | | | | | | 1795 calls of functionODE | | | | | | 195 evaluations of jacobian | | | | | | 96 error test failures | | | | | | 6 convergence test failures | | | | | | 0.0188303s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.