Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_10_Buildings.Air.Systems.SingleZone.VAV.Examples.ChillerDXHeatingEconomizer.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/package.mo", uses=false) Using package Buildings with version 10.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Buildings.Air.Systems.SingleZone.VAV.Examples.ChillerDXHeatingEconomizer,tolerance=1e-06,outputFormat="mat",numberOfIntervals=280,variableFilter="time|con.TRoo|con.TSetRooHea|con.TSetRooCoo|EFan.y|EHea.y|ECoo.y|EHVAC.y|EPum.y",fileNamePrefix="Buildings_10_Buildings.Air.Systems.SingleZone.VAV.Examples.ChillerDXHeatingEconomizer") translateModel(Buildings.Air.Systems.SingleZone.VAV.Examples.ChillerDXHeatingEconomizer,tolerance=1e-06,outputFormat="mat",numberOfIntervals=280,variableFilter="time|con.TRoo|con.TSetRooHea|con.TSetRooCoo|EFan.y|EHea.y|ECoo.y|EHVAC.y|EPum.y",fileNamePrefix="Buildings_10_Buildings.Air.Systems.SingleZone.VAV.Examples.ChillerDXHeatingEconomizer") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001029/0.001029, allocations: 91.14 kB / 15.06 MB, free: 1.098 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001358/0.001358, allocations: 172.7 kB / 15.95 MB, free: 208 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.572/1.572, allocations: 223.3 MB / 240 MB, free: 5.422 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/package.mo): time 2.592/2.592, allocations: 437.7 MB / 0.7117 GB, free: 7.094 MB / 0.5606 GB Notification: Performance of FrontEnd - loaded program: time 0.0003159/0.000316, allocations: 8 kB / 0.8722 GB, free: 3.699 MB / 0.7169 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5648/0.5651, allocations: 153.8 MB / 1.022 GB, free: 40 kB / 0.7637 GB Notification: Performance of NFInst.instantiate(Buildings.Air.Systems.SingleZone.VAV.Examples.ChillerDXHeatingEconomizer): time 0.9635/1.529, allocations: 463.5 MB / 1.475 GB, free: 11.46 MB / 1.061 GB Notification: Performance of NFInst.instExpressions: time 0.1206/1.649, allocations: 87.31 MB / 1.56 GB, free: 3.961 MB / 1.139 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.02055/1.67, allocations: 488.9 kB / 1.561 GB, free: 3.48 MB / 1.139 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFEvalFunction.mo:718:9-721:52:writable] Error: Internal error NFEvalFunction.assignArrayElement: unimplemented case for fill(0.0, 9)[1] = 7e-07 Notification: Performance of FrontEnd: time 0.005637/1.676, allocations: 2.044 MB / 1.563 GB, free: 1.43 MB / 1.139 GB