Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WaterHeater_u.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatExchangers.Examples.WaterHeater_u,fileNamePrefix="Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WaterHeater_u",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.HeatExchangers.Examples.WaterHeater_u,fileNamePrefix="Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WaterHeater_u",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008002/0.0008001, allocations: 91.38 kB / 15.06 MB, free: 1.098 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009584/0.0009584, allocations: 172.7 kB / 15.95 MB, free: 208 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.321/1.321, allocations: 223.3 MB / 240 MB, free: 5.32 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.467/2.467, allocations: 409.4 MB / 0.684 GB, free: 0.9805 MB / 0.5294 GB Notification: Performance of FrontEnd - loaded program: time 0.0003545/0.0003546, allocations: 8 kB / 0.8378 GB, free: 6.559 MB / 0.6856 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.718/0.7184, allocations: 146.8 MB / 0.9811 GB, free: 6.32 MB / 0.7325 GB Notification: Performance of NFInst.instantiate(Buildings.Fluid.HeatExchangers.Examples.WaterHeater_u): time 0.05516/0.7736, allocations: 62.16 MB / 1.042 GB, free: 7.988 MB / 0.795 GB Notification: Performance of NFInst.instExpressions: time 0.02372/0.7974, allocations: 17.4 MB / 1.059 GB, free: 6.555 MB / 0.8106 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.004507/0.8019, allocations: 79.5 kB / 1.059 GB, free: 6.477 MB / 0.8106 GB [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFEvalFunction.mo:718:9-721:52:writable] Error: Internal error NFEvalFunction.assignArrayElement: unimplemented case for fill(0.0, 9)[1] = 7e-07 Notification: Performance of FrontEnd: time 0.00573/0.8077, allocations: 1.798 MB / 1.061 GB, free: 4.676 MB / 0.8106 GB