OMSimulator -r=Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.ThermalZones.Validation.Alarms_res.mat --tempDir=temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms_fmu --startTime=0 --stopTime=7200 --timeout=50 --tolerance=1e-06 Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.ThermalZones.Validation.Alarms/temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.ThermalZones.Validation.Alarms" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.ThermalZones.Validation.Alarms/temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_ThermalZones_Validation_Alarms_fmu/model-4u30wzfa" info: model doesn't contain any continuous state info: No result file will be created warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated at time 1741.818182 not zonAla.tenMinDur4.y assert | warning | Warning: the zone CO2 concentration exceeds setpoint plus 10%.0 warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated at time 3923.636364 zonAla.not3.y assert | warning | Warning: zone temperature is 2 degC lower than the heating setpoint warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated at time 4069.090909 zonAla.not4.y assert | warning | Warning: zone temperature is 3 degC lower than the heating setpoint warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated at time 4432.727273 zonAla.not5.y assert | warning | Warning: the zone CO2 concentration exceeds 600 ppm in unoccupied mode. The CO2 sensor may be out of calibration. info: 4 warnings info: 0 errors